DU-2/MKII
May 12, 2026

DU-2/MKII

Description

1. Product Overview

The DU-2/MKII is a second-generation MKII high-performance divided-potential electrochemical trace oxygen sensor.
It is optimized and upgraded on the basis of classic DU series structure, adopting improved electrolyte formula and enhanced anti-poisoning design. It is dedicated to ppm-level ultra-low oxygen detection, featuring higher stability, lower drift, faster response and wider temperature adaptability.
With standard DU interface, it is fully compatible with DIM signal modules, DELOMATIC controller and DPD series mounting bases, widely used in industrial inert gas monitoring, semiconductor process, laboratory glove box and professional oxygen analysis instruments.

2. Key Features

  • MKII second-generation upgraded version, optimized internal formula

  • High precision ppm-level trace oxygen measurement

  • Fast T90 response and rapid signal recovery

  • Ultra-low monthly drift, excellent long-term stability

  • Improved temperature resistance, small temperature coefficient

  • Enhanced anti-interference and anti-poisoning capability against mixed gases

  • Standard DU interface, plug-and-play replacement

  • Sealed compact structure, easy installation and field maintenance

  • Long service life, suitable for 24-hour continuous online monitoring

3. Technical Specifications

3.1 Performance Parameters

ParameterSpecification
ModelDU-2/MKII
Working PrincipleDivided-potential Electrochemical Oxygen Sensor
Measuring Range0~10 ppm (custom range optional)
T90 Response Time≤ 7 s
Accuracy±2% FS
Linearity Error≤ ±2% FS
Monthly Long-term Drift≤ 0.8% FS
Temperature Coefficient≤ 2.8%/°C
Operating Temperature0°C ~ +50°C
Working Humidity0%~95% RH, non-condensing
Working Pressure80~120 kPa
Service Life≥ 24 months
Shelf Life12 months (sealed original package)

3.2 Mechanical & Interface Parameters

ParameterSpecification
StructureCylindrical standard DU package
Interface TypeDU standard concentric ring interface
Housing MaterialHigh-density polyethylene HDPE
Net WeightApprox. 5 g
Matching BaseDPD02027 / DPD08063
Matching ModuleDIM5-1 / DELOMATIC-3/DGU1

4. Application Scope

  • Nitrogen, argon, hydrogen industrial trace oxygen online monitoring

  • Semiconductor manufacturing process gas and protective atmosphere detection

  • Laboratory glove box, inert atmosphere furnace and vacuum cabinet

  • Portable trace oxygen analyzer and fixed online monitoring equipment

  • Petrochemical, metallurgy shielding gas pipeline monitoring

  • Food and pharmaceutical packaging residual oxygen detection system

5. Installation & Operation Guide

5.1 Installation

  1. Install vertically with the gas inlet facing upward, keep the vent unobstructed.

  2. Use matched DPD dedicated base; insert vertically in place, do not twist forcibly.

  3. Adopt sealed gas path connection; PTFE tube is recommended.

  4. Recommended gas flow: 200~500 mL/min; avoid over-speed airflow impact.

  5. Keep away from high temperature, strong vibration and corrosive gas environment.

5.2 Preheating & Calibration

  1. Power on and preheat for 10–15 minutes before calibration and official use.

  2. Zero Calibration: Use high-purity nitrogen (0 ppm O₂) to set zero point.

  3. Span Calibration: Use standard low oxygen gas for span calibration.

  4. When ambient temperature or working condition changes greatly, recalibration is required.

6. Safety Precautions

  • Non-explosion-proof design; prohibited for direct use in flammable and explosive hazardous areas.

  • Prevent condensed water, oil mist and dust from entering the air inlet.

  • Take anti-static protection during handling and installation.

  • Do not disassemble the sensor shell privately to avoid electrolyte leakage and permanent failure.

  • Avoid long-term exposure to strong corrosive gases such as SO₂, Cl₂ and H₂S.

7. Maintenance & Storage

  • Regular zero and span calibration every 3–6 months according to application environment.

  • Keep the inlet filter clean; replace it once blocked or contaminated.

  • Store in sealed package at 10~30°C, 30%~70% RH, cool dry place.

  • Avoid direct sunlight, high temperature and damp stacking.

8. Troubleshooting

Fault PhenomenonPossible CauseSolution
No signal outputPoor contact / wrong insertion directionReinstall sensor; check DPD base terminal
Unstable readingInsufficient preheating / airflow fluctuationFully preheat; stabilize gas flow
Slow responseAir inlet blocked / sensor agingClean filter; recalibrate or replace sensor
Large driftTemperature mutation / overdue calibrationTemperature compensation + recalibration

9. Warranty & Disclaimer

  • Product Model: DU-2/MKII Trace Oxygen Sensor

  • Warranty Period: 12 months from delivery date under normal installation and use.

  • Warranty void for damage caused by forced disassembly, improper installation, liquid immersion and human damage.

  • All specifications are subject to technical upgrade without prior notice.

  • The manufacturer reserves the right of final interpretation of product structure and parameters。