DIM5-1
May 12, 2026

DIM5-1

Description

1. Product Overview

DIM5-1 is a high-performance intelligent signal acquisition and conversion module, specially designed to match electrochemical oxygen sensors and other gas sensors.
It realizes sensor signal amplification, filtering, temperature compensation, linear correction and standard signal output. With compact structure, high measurement accuracy, strong anti-interference ability and stable long-term operation, it is widely used in industrial online gas monitoring, laboratory analysis equipment, portable detectors and supporting instrument systems.

2. Key Features

  • High-precision signal conditioning for gas sensors

  • Built-in automatic temperature compensation algorithm

  • Excellent linear correction, low zero drift

  • Multiple output modes: analog 4–20mA + RS485 Modbus-RTU

  • Industrial grade EMC anti-interference design

  • Miniature modular design, easy installation and embedded integration

  • Low power consumption, suitable for long-term continuous operation

  • Support one-key zero calibration and span calibration

  • Wide supply voltage range, convenient field wiring

3. Technical Specifications

3.1 Electrical Parameters

ParameterSpecification
ModelDIM5-1
Input PowerDC 12~24V
Working Current≤ 70mA
Input SignalWeak current signal from electrochemical sensor
Measurement RangeCustomizable 0–10ppm / 0–100ppm / 0–1000ppm
Accuracy±2% FS
Resolution0.01ppm
Warm-up Time≤ 5min
Analog Output4~20mA isolation output
Digital InterfaceRS485, Modbus-RTU protocol
Baud Rate2400 / 4800 / 9600 / 19200 optional

3.2 Environmental Parameters

ParameterSpecification
Operating Temperature0℃ ~ +50℃
Operating Humidity10%~95% RH, non-condensing
Storage Temperature-20℃ ~ +60℃
Working Pressure80kPa~120kPa
Protection GradeIP40

3.3 Mechanical Parameters

ParameterSpecification
InstallationScrew fixing / DIN rail mounting
Shell MaterialHigh-strength engineering plastic
WeightApprox. 40g
OutlineCompact rectangular modular size

4. Application Scope

  • Matching use with AOP / CM / CRM series oxygen sensors

  • Industrial nitrogen, argon, hydrogen trace oxygen online monitoring

  • Semiconductor process gas detection and protection atmosphere monitoring

  • Laboratory glove box, inert gas cabinet atmosphere analysis

  • Portable gas detector and fixed online analyzer supporting module

  • Petrochemical, metallurgy, food and pharmaceutical residual oxygen monitoring system

5. Pin Definition & Wiring

  1. Power Interface

  • VCC:DC 12~24V Positive

  • GND:Power Ground & Signal Common Ground

  1. Sensor Interface

  • SEN+ / SEN-:Sensor signal differential input

  1. Signal Output

  • 4-20mA+ / 4-20mA-:Analog isolated output

  • A / B:RS485 communication line

6. Installation & Operation Guide

6.1 Installation

  1. Install horizontally, avoid direct sunlight and heat radiation.

  2. Keep away from high-power frequency conversion equipment and strong electromagnetic interference sources.

  3. Sensor signal wire adopts shielded wire, separated from power line layout.

  4. Ensure reliable grounding to improve anti-interference performance.

6.2 Calibration Steps

  1. Power on the module and preheat for at least 5 minutes.

  2. Zero Calibration:Feed high-purity nitrogen (0ppm) to complete zero point calibration.

  3. Span Calibration:Access standard gas with known concentration for span calibration.

  4. The module automatically saves calibration parameters and enters normal measurement state.

7. Safety Precautions

  • Do not apply overvoltage power supply to prevent module permanent damage.

  • Prohibit use in flammable, explosive and strong corrosive environments without protection.

  • Do not disassemble the shell privately; unauthorized disassembly will void warranty.

  • Prevent liquid, dust and oil from entering the wiring port and shell.

  • In thunderstorm weather, strengthen grounding and lightning protection measures.

8. Daily Maintenance

  • Check wiring terminals regularly every 3 months for looseness and oxidation.

  • Recalibrate every 3–6 months according to working environment.

  • Keep module surface clean and dry, avoid dust accumulation.

  • For long-term shutdown, cut off power supply and store in dry and ventilated place.

9. Troubleshooting

Fault PhenomenonPossible CauseSolution
No power and no responseAbnormal power input / wiring errorCheck DC power supply and wiring polarity
Large reading driftInsufficient warm-up / sensor agingFully preheat; recalibrate or replace sensor
No 4–20mA outputOutput wiring error / channel faultCheck analog output connection
RS485 communication failureA/B line reversed / address conflictSwap A and B line; modify device address
Unstable fluctuation valueElectromagnetic interference / poor groundingUse shielded wire and reliable grounding

10. Warranty & Disclaimer

  • Product Model:DIM5-1 Signal Conversion Module

  • Warranty Period:12 months from delivery date under normal installation and use

  • The warranty does not cover damage caused by wrong wiring, overvoltage, unauthorized disassembly and man-made damage.

    All specifications are subject to change without prior notice. The manufacturer reserves the right to optimize product structure and performance


Get a Quote