AOP-1.1DU2.1DGU-7
May 12, 2026

AOP-1.1DU2.1DGU-7

Description

AOP-1.1DU2.1DGU-7 Trace Oxygen Sensor Datasheet

1. Product Overview

The AOP-1.1DU2.1DGU-7 is a high-precision divided-potential electrochemical trace oxygen sensor from ASAIR (Guangzhou Aosong Electronics Co., Ltd.), designed for ultra-low oxygen concentration detection. It delivers accurate, reliable ppm-level oxygen measurements via electrochemical reaction current output, featuring a compact design, low detection limit, fast response, and exceptional long-term stability. Ideal for industrial, medical, and gas separation applications requiring stringent trace oxygen monitoring.

2. Key Features

  • Ultra-low detection range: 0–10 ppm (custom ranges up to 10,000 ppm available).

  • Rapid response: T90 response time <7 seconds.

  • High accuracy: ±2% full-scale (F.S.) precision.

  • Self-powered operation: No external power supply required.

  • Superior stability: Monthly drift <1%; linearity ±2% F.S..

  • Robust build: HDPE housing for durability in harsh environments.

  • Compact form factor: Space-saving design for easy integration into devices.

3. Technical Specifications

3.1 Electrical Parameters

表格
ParameterValue
Working PrincipleDivided-potential electrochemical
Output Current1295–700 μA (in ambient air)
Measurement Range0–10 ppm (customizable: 0–10,000 ppm)
Response Time (T90)<7 s
Accuracy±2% F.S.
Linearity±2% F.S.
Monthly Drift<1%
Temperature Coefficient3.0%/°C
Electrical InterfaceGold-plated concentric rings (inner: negative, outer: positive)

3.2 Mechanical Parameters

表格
ParameterValue
Housing MaterialHDPE (High-Density Polyethylene)
DimensionsCustom (compact, device-integration optimized)
Weight~5 g

3.3 Environmental Parameters

表格
ParameterValue
Operating Temperature0–45°C
Operating Humidity0–99% RH (non-condensing)
Operating PressureAtmospheric pressure ±20%
Expected Lifespan>2 years (in air)
Shelf Life12 months (from delivery date)

4. Application Scope

  • Industrial Process Control: Nitrogen/hydrogen production, natural gas pipelines, semiconductor manufacturing, petrochemicals.

  • Medical Industry: Anesthesia gas monitoring, respiratory equipment, medical oxygen analyzers.

  • Gas Separation: Oxygen monitoring in nitrogen/argon separation systems.

  • Environmental Monitoring: Emission gas analysis, hazardous gas detection.

  • Safety Equipment: Oxygen alarms, portable gas detectors, fixed gas monitoring systems.

5. Installation & Operation Guidelines

5.1 Installation

  1. Orientation: Mount vertically with the gas inlet facing downward to prevent liquid ingress.

  2. Wiring: Connect inner gold-plated ring to negative (−), outer ring to positive (+) of the measurement circuit.

  3. Gas Connection: Use 1/8-inch or 3 mm PTFE tubing; maintain flow rate 200–500 mL/min (avoid excessive flow to prevent damage).

5.2 Operation

  1. Warm-Up: Allow 15-minute warm-up after installation for stable readings.

  2. Calibration:

    • Zero Calibration: Expose to 100% nitrogen (0 ppm O₂) and adjust zero offset.

    • Span Calibration: Expose to a known concentration (e.g., 10 ppm) and adjust span gain.

  3. Reading: The sensor outputs a current signal proportional to oxygen concentration; convert to ppm via the calibration curve.

6. Safety & Maintenance

6.1 Safety Precautions

  • Non-explosion-proof: Do not use in flammable/explosive atmospheres.

  • No liquid contact: Avoid exposure to water, oil, or corrosive gases (e.g., Cl₂, SO₂).

  • ESD protection: Use anti-static gloves during handling to prevent electrostatic damage.

6.2 Maintenance

  • Regular Calibration: Perform zero/span calibration every 3–6 months (depending on usage).

  • Filter Replacement: Replace the inlet filter every 6 months to prevent dust contamination.

  • Storage: Store in a cool, dry place (10–30°C, 30–70% RH) in sealed packaging; avoid direct sunlight.

7. Troubleshooting

表格
IssuePossible CauseSolution
No OutputWiring error or sensor damageCheck wiring; replace sensor if faulty
Unstable ReadingsInsufficient warm-up or flow fluctuationWarm up for 15 min; stabilize gas flow
Slow ResponseContaminated filter or sensor agingReplace filter; recalibrate or replace sensor
Large DriftTemperature variation or expired calibrationCompensate for temperature; recalibrate

8. Manufacturer Information

  • Brand: ASAIR (Guangzhou Aosong Electronics Co., Ltd.)

  • Address: No. 10, Kexue Avenue, Science City, Guangzhou, China

  • Website: www.aosong.com

  • Support Email: support@aosong.com

  • Tel: +86-20-3229 8888

9. Quality Guarantee

ASAIR warrants the AOP-1.1DU2.1DGU-7 to be free from defects in materials and workmanship for 12 months from the delivery date. This warranty excludes damage from misuse, improper installation, or harsh environmental exposure.

Disclaimer

Specifications are subject to change without notice. ASAIR reserves the right to modify product design and performance to enhance quality.


Get a Quote