MVI56-104S

Model: MVI56‑104S Manufacturer: ProSoft Technology (inRAx series) Platform: Allen‑Bradley ControlLogix (1756 chassis, single‑slot) Protocol: IEC 60870‑5‑104 Server (Slave) (TCP/IP Ethernet for substation SCADA) Function: Enables ControlLogix PLC to act as an IEC 104 server, exchanging data with IEC 104 client SCADA masters (electric utility control centers). Data Exchange: 4000‑word internal register space between ControlLogix tags and Ethernet; supports time‑stamped events, TRBE (Report by Exception).

Description

1. Product Overview

  • Model: MVI56‑104S

  • Manufacturer: ProSoft Technology (inRAx series)

  • Platform: Allen‑Bradley ControlLogix (1756 chassis, single‑slot)

  • Protocol: IEC 60870‑5‑104 Server (Slave) (TCP/IP Ethernet for substation SCADA)

  • Function: Enables ControlLogix PLC to act as an IEC 104 server, exchanging data with IEC 104 client SCADA masters (electric utility control centers).

  • Data Exchange: 4000‑word internal register space between ControlLogix tags and Ethernet; supports time‑stamped events, TRBE (Report by Exception).

2. Key Features

  • Dual 10/100 Mbps Ethernet ports (P1, P2) for redundant network

  • IEC 104 server compliance: Supports ASDU types, time synchronization, TRBE

  • Client connections: Up to 8 concurrent IEC 104 clients

  • Data capacity: 4000 words (8000 bytes) shared I/O database

  • Event reporting: Unsolicited messages (spontaneous/cyclic) with millisecond time stamps

  • Diagnostic LEDs: PWR, RUN, BP LINK, P1 LINK/ACT, P2 LINK/ACT

  • Configuration: ProSoft Configuration Builder (PCB)

  • Approvals: CE, UL/cUL, CSA, ATEX, RoHS

3. Technical Specifications

General

  • Slot usage: 1 slot (1756 local/remote rack)

  • Backplane current: 800 mA @ 5 VDC

  • Data mapping: Direct tag access + 4000‑word shared database

  • Firmware: Field‑upgradeable via PCB

Ethernet Interface (P1/P2)

  • Standard: IEC 60870‑5‑104 (TCP/IP), 10/100Base‑TX

  • Connector: RJ45 (two ports, switchable redundancy)

  • Max clients: 8 simultaneous IEC 104 client connections

  • Data types: Analog, binary, counter, SOE, setpoints, parameters

Environmental

  • Operating temp: 0°C to +60°C (32°F to 140°F)

  • Storage temp: ‑40°C to +85°C

  • Humidity: 5%–95% non‑condensing

  • Vibration: 5 g (10–150 Hz)

  • Shock: 30 g (operational)

4. LED Indicators

  • PWR: On = backplane power OK

  • RUN: On = module operational; flashing = firmware activity

  • BP LINK: On = backplane communication active

  • P1/P2 LINK: On = Ethernet link established

  • P1/P2 ACT: Flashing = Ethernet data traffic

5. Installation & Configuration

  1. Power off ControlLogix chassis.

  2. Insert MVI56‑104S into empty 1756 slot.

  3. Connect Ethernet cables to P1/P2; connect PC for configuration.

  4. Power on; verify module in Studio 5000 I/O tree.

  5. Use ProSoft Configuration Builder (PCB) to set:

    • Ethernet IP addresses, subnet, gateway

    • IEC 104 server parameters (ASDU, cause of transmission)

    • Tag mapping (ControlLogix tags ↔ 4000‑word database)

  6. Download configuration; test with IEC 104 client simulator/SCADA.

6. Applications

  • Power substations: ControlLogix as IEC 104 server for SCADA master monitoring

  • Utility SCADA: Real‑time telemetry (analog/binary), SOE, fault recording

  • Renewable energy: Wind/solar farm data reporting to grid control centers

  • Water/wastewater: Remote plant monitoring via IEC 104 Ethernet

  • Petrochemical: Process data exchange with enterprise SCADA

7. Advantages

  • IEC 104 server for Rockwell: Native Ethernet integration for ControlLogix

  • Dual Ethernet redundancy: High availability for critical substation networks

  • Real‑time events: TRBE + millisecond time stamps for accurate SOE

  • Large data pool: 4000 words for extensive I/O and parameters

  • Seamless Rockwell workflow: Studio 5000 tags, no custom logic required