MVI46-DFCM
Description

1. Product Overview
2. Main Features
Fully compliant with standard Rockwell DF1 serial communication protocol
Equipped with two independent isolated serial communication ports
Support RS-232 and RS-485 electrical interface selection
Each port can be independently configured as master station or slave station
Support full-duplex and half-duplex communication modes freely switchable
Built-in large-capacity register database up to 5000 words
Realize data interaction with SLC CPU through M0 and M1 data files
Provide complete ready-made ladder logic program for fast application
Support configuration via ProSoft Configuration Builder software
Independent protocol processing design will not occupy main controller operation resources
3. Technical Specifications
Communication Parameters
Power Specification
Environmental Performance
Physical Installation
4. LED Status Description
5. Installation and Configuration Steps
Cut off all power of SLC 500 control system
Insert MVI46-DFCM module into empty slot of 1746 chassis
Connect external DF1 communication equipment to corresponding serial interface
Power on the system and confirm the module is recognized successfully
Set communication mode, station address and serial port parameters via configuration tool
Configure internal data mapping relation according to actual transmission demand
Import matching ladder program to complete data area matching
Download all configurations and user programs to controller
Conduct online communication test to verify data receiving and sending normally
6. Application Scope
Data interconnection between multiple Allen-Bradley PLC equipments
On-site HMI man-machine interface DF1 serial connection communication
Industrial SCADA system remote data collection and monitoring
Transformation and upgrading of old equipment with traditional DF1 communication interface
Factory production line distributed control system data interaction
Building automatic control and mechanical equipment serial signal transmission
7. Product Advantages
Standard DF1 protocol design, excellent compatibility with AB series automation products
Dual-port independent design can build two sets of DF1 communication networks at the same time
Flexible master-slave mode switching meets diverse networking demands
Simple system integration, no complex secondary protocol development required
Stable industrial-grade performance, suitable for long-term continuous field operation
Complete diagnosis function, easy daily maintenance and rapid fault location
8. Safety Operation Notes
All plugging, wiring and maintenance operations must be done under power-off state
Correctly distinguish RS-232 and RS-485 wiring definitions to avoid interface damage
Keep consistent baud rate, parity and station address among all communication devices
Reasonably plan communication address to prevent address conflict and data confusion
Add terminal matching resistance for long-distance RS-485 transmission
Avoid using the module beyond specified temperature and humidity working range