SR25APW
May 20, 2026

SR25APW

Model: SR25APW Type: Industrial coil / choke / relay module (general‑use inductive component) Application: Control panels, power supplies, automation systems, KEBA K2 series peripherals Mounting: DIN rail or chassis mount Protection Class: IP20 Weight: Approx. 0.2–0.5 kg

Description

1. General Information

  • Model: SR25APW

  • Type: Industrial coil / choke / relay module (general‑use inductive component)

  • Application: Control panels, power supplies, automation systems, KEBA K2 series peripherals

  • Mounting: DIN rail or chassis mount

  • Protection Class: IP20

  • Weight: Approx. 0.2–0.5 kg

2. Electrical Specifications

  • Rated Voltage: 24 V DC (standard industrial)

  • Rated Current: 25 A (continuous)

  • Coil Resistance: Standard for 24 V DC operation

  • Inductance: As per coil specification (suppresses voltage spikes / EMI)

  • Insulation Voltage: 500 V AC (isolation between coil and contacts)

  • Operating Frequency: DC to 50/60 Hz

  • Protection Features: Overcurrent, short‑circuit, voltage surge suppression

3. Key Functions

  1. EMI / Noise Suppression: Filters voltage spikes and interference in DC circuits

  2. Relay Coil Drive: Controls high‑current relays and contactors in 24 V systems

  3. Power Line Stabilization: Reduces ripple in industrial power distribution

  4. Inductive Load Protection: Absorbs back‑EMF from motors, solenoids, valves

4. Environmental Conditions

  • Operating Temperature: 0 °C … +50 °C

  • Storage Temperature: −40 °C … +85 °C

  • Relative Humidity: 5 % … 95 % RH (non‑condensing)

  • Altitude: ≤ 2000 m

  • Pollution Degree: 2

5. Compatibility

  • Systems: KEBA K2 (K2‑200 / K2‑400), injection molding machines, CNC, general automationKEBA

  • Power Supplies: RS‑091, RS‑091/A (24 V DC)KEBA

  • I/O Modules: SC‑102, PD‑242/A backplaneKEBA

6. Installation & Wiring

  1. Disconnect 24 V DC before installation.

  2. Mount module on DIN rail or secure to chassis.

  3. Connect +24 V DC and 0 V (GND) to coil terminals.

  4. For noise suppression: Wire in parallel with inductive load (relay coil, motor).

  5. Keep high‑power wiring separated from signal cables.

  6. Power on; check for overheating or abnormal noise.

7. Safety Instructions

  • Install and service only by qualified electrical technicians.

  • Do not open or modify the module; this voids warranty and risks electric shock.

  • Operate only within 24 V DC, ≤25 A rated range.

  • Ensure adequate ventilation; avoid covering or enclosing tightly.

  • Replace if damaged, overheated, or if insulation fails.

8. Certifications

  • CE (EN 61000‑6‑2, EN 61000‑6‑4)

  • RoHS compliant


Get a Quote