31C007-503-4-00
Description
1. Model Code Definition
2. Electrical Specifications
Rated Output Power: 0.75 kW
Input Voltage: 3-phase AC 380~480 V
Rated Frequency: 50 Hz / 60 Hz
Rated Continuous Output Current: 2.4 A
Output Voltage Range: 0~480 V three-phase AC
Output Frequency Range: 0~400 Hz
Control Mode: V/F open-loop / Sensorless vector control
Overload Capacity: 150% rated current for 60 seconds
Switching Frequency: 4kHz, 8kHz, 12kHz, 16kHz optional
Standard built-in STO Safe Torque Off function
3. Environmental & Physical Parameters
Protection Class: IP20
Cooling Method: Natural air cooling without fan
Operating Temperature: 0°C ~ +45°C full load operation
Storage Temperature: -25°C ~ +70°C
Working Humidity: 5%~95%, non-condensing
Installation Way: Vertical wall mounting
Max Working Altitude: Below 1000 meters without power reduction
Applicable Environment: Light industrial working occasions
4. Standard Communication & Terminals
Onboard RS485 interface, support Modbus RTU protocol
Analog signal input: 0-10V DC / 0-20mA dual mode
6 groups 24V DC programmable digital input terminals
2 groups programmable relay output terminals
PTC motor over-temperature protection input port
External brake resistor connecting terminal
Multi-speed fixed frequency control terminals
Optional external operation panel for parameter setting
5. Main Operating Functions
Acceleration and deceleration time adjustable from 0.1s to 600s
Built-in DC braking and dynamic braking for fast stop
Intelligent energy saving running mode
Three control modes: local panel, external terminal, remote communication
Slip compensation function to stabilize running speed
Soft start and soft stop to reduce starting current and mechanical impact
Integrated PID closed-loop control for constant speed and constant pressure
Support parameter saving, copying and one-click restoration
Excellent low speed high torque output performance
6. Complete Protection Functions
Instantaneous overcurrent and thermal overload protection
Over voltage and under voltage fault protection
Three-phase input phase loss detection protection
Inverter internal overheating protection
Electronic thermal motor overload protection
Output circuit short circuit protection
Motor ground fault protection
Running anti-stall protection
Control terminal static electricity protection
Hardware STO safety torque off protection
7. Installation & Wiring Rules
Cut off all power supply before wiring, debugging and maintenance
Separate power lines and control signal lines to avoid interference
Ensure reliable connection of PE grounding terminal
Reserve enough space around for heat dissipation
Do not install in dusty, humid, oily and corrosive environment
It is recommended to use shielded special motor cables for output wiring
8. Basic Commissioning Steps
Check all wiring to confirm no wrong connection and short circuit risk
Confirm on-site input voltage matches inverter rated voltage
Set motor rated voltage, current, frequency and speed parameters correctly
Select proper control mode according to actual use requirements
Set reasonable acceleration/deceleration time and frequency limit value
Carry out no-load test run first to check motor running direction and sound
Put into formal load operation after stable no-load operation
9. Daily Maintenance Instructions
Clean surface dust regularly every three to six months
Check the tightness of all wiring terminals periodically
Observe real-time operating current and temperature during operation
All fault inspection and maintenance work must be completed by qualified electricians