3005-403-4-00
Description



3005-403-4-00
SEW MOVITRAC Frequency Inverter English Detailed Specification
1. Model Code Definition
2. Electrical Technical Parameters
Rated Power: 15 kW
Input Voltage: 3-phase AC 200~240 V (Nominal 230 V)
Input Frequency: 50 Hz / 60 Hz
Rated Output Current: 58.0 A
Output Voltage: 0~230 V three-phase AC
Output Frequency Range: 0~400 Hz
Control Mode: V/F open-loop control
Overload Capacity: 150% rated current for 60 seconds
Carrier frequency: Adjustable
3. Physical & Environmental Parameters
Protection Class: IP20
Cooling Mode: Built-in fan forced air cooling
Operating Temperature: 0 °C ~ +45 °C
Storage Temperature: -25 °C ~ +70 °C
Working Humidity: 5%~95%, non-condensing
Installation Mode: Vertical wall mounting
Application altitude: ≤1000m without power derating
4. Standard External Interfaces
Onboard RS485 communication interface
Multi-channel digital input / relay signal output terminals
0-10V analog speed regulating input interface
Multi-segment fixed speed control terminal
External motor overheating protection access port
5. Main Operating Functions
Acceleration and deceleration time adjustable freely
Built-in dynamic braking unit for fast stop
Intelligent energy-saving operation mode
Support keyboard local control, terminal control and remote communication control
Speed slip compensation function to stabilize running speed
Soft start & soft stop reduce mechanical impact
Automatic voltage stabilization function
6. Full-range Protection Functions
Overcurrent protection
Overvoltage & undervoltage protection
Input phase loss protection
Inverter over temperature protection
Motor overload electronic thermal protection
Output short circuit protection
Ground fault protection
Running stall prevention protection
7. Installation and Wiring Rules
Cut off all power supply before wiring and maintenance
Power cables and control cables must be laid separately
Must connect reliable PE protective grounding wire
Reserve enough ventilation space around for heat dissipation
Avoid dusty, humid, oil mist and strong vibration installation environment
It is recommended to use shielded special motor cables for output lines
8. Commissioning Operation Steps
Check all wiring to confirm no wrong wiring and short circuit
Confirm that the input power supply voltage is consistent with the inverter specification
Set motor rated voltage, rated current, upper and lower limit frequency parameters
Select the corresponding control mode according to on-site requirements
First perform no-load trial operation to check operating sound and status
After confirming normal operation, gradually load for formal use
9. Daily Maintenance Items
Regularly clean cooling fan and internal dust
Regularly check whether each terminal is loose
Real-time monitor operating current and internal temperature
Timely replace aging and damaged cooling fans
Fault inspection and maintenance must be operated by professional electricians