3001-403-4-00
Description


3001-403-4-00
SEW MOVITRAC Frequency Inverter Detailed English Manual
1. Model Code Explanation
2. Electrical Specifications
Rated Power: 4.0 kW
Input Voltage: 3-phase AC 200~240V (Nominal 230V)
Input Frequency: 50Hz / 60Hz
Rated Output Current: 17.0 A
Output Voltage: 0~230V 3-phase AC
Output Frequency Range: 0~400Hz
Control Mode: V/F open-loop control
Overload Capacity: 150% rated current for 60 seconds
3. Physical & Environmental Parameters
Protection Class: IP20
Cooling Mode: Forced air cooling
Operating Temperature: 0°C ~ +45°C
Storage Temperature: -25°C ~ +70°C
Working Humidity: 5%~95%, non-condensing
Installation: Vertical wall mounting
Application Altitude: ≤1000m without power derating
4. Control Interfaces & Functions
Standard built-in RS485 communication interface
Multi-channel digital input and relay output terminals
0-10V analog speed regulation input port
Multi-section fixed speed operation function
Adjustable acceleration / deceleration time
Built-in dynamic braking function for fast stop
Support local panel, external terminal and remote communication control
Energy-saving running mode
5. Complete Protection Functions
Over current protection
Over voltage & under voltage protection
Inverter over temperature protection
Motor overload electronic thermal protection
Output short circuit protection
Earth fault protection
Stall prevention protection
Phase loss protection
6. Installation & Wiring Requirements
Cut off all power supply before wiring and maintenance
Separate power cables and control cables to reduce electromagnetic interference
Connect reliable PE protective grounding wire strictly
Reserve sufficient ventilation space around the inverter for heat dissipation
Avoid installation in dusty, damp, corrosive gas and strong vibration sites
It is recommended to use shielded motor special cable for output wiring
7. Commissioning Steps
Check wiring correctness and no short circuit
Confirm power supply voltage matches inverter specification
Power on and restore factory parameters if needed
Set motor rated voltage, rated current, limit frequency and acceleration/deceleration time
Select applicable control mode
Run no-load test firstly, confirm no abnormal noise and vibration
Put into formal load operation after normal test run
8. Daily Maintenance
Regularly clean internal dust and cooling fan dirt
Check tightness of power terminals and control terminals periodically
Monitor running current and operating temperature in real time
Replace aging cooling fan regularly for long-term continuous operation
Fault inspection and repair must be operated by professional electricians