2551
Description


TRICONEX 2551
Analog Input Module (8‑Channel, TMR, 4–20 mA / 0–10 VDC, SIL 3)
Official Specification & User Manual (English)
1. General Description
2. Part Number & Type
Model: 2551
Type: Analog Input Module (AI), TMR
Series: Trident (Triconex / Schneider Electric)
Safety Level: SIL 3 (IEC 61508)
Approvals: TÜV Rheinland, FM, CSA
3. Key Features
8 Isolated Analog Input Channels
Configurable for 4–20 mA or 0–10 VDC transmitters/sensors.
Triple Modular Redundancy (TMR)
2oo3 voting; three independent measurement paths per channel.
High Accuracy & Stability
±0.02% F.S., 1000 samples/sec, low drift over temperature.
Per‑Channel Isolation
2500 V RMS channel‑to‑backplane isolation.
Advanced Diagnostics
Open circuit, short circuit, out‑of‑range, over‑temperature, drift alarm.
Hot‑Swappable
Replace online without system shutdown.
SIL 3 Fault Coverage
99% diagnostic coverage for safe and dangerous faults.
4. Technical Specifications
4.1 Input Channels
Number: 8 channels, isolated, single‑ended
Signal Types: 4–20 mA (default), 0–10 VDC (configurable)
Resolution: 16‑bit
Accuracy: ±0.02% F.S. @ 25°C
Repeatability: ±0.005% F.S.
Sampling Rate: 1000 Hz per channel
Input Impedance:
4–20 mA: 100 Ω
0–10 VDC: >1 MΩ
4.2 Safety & Redundancy
Architecture: TMR, 2oo3 voting
Safety Integrity Level: SIL 3
Fault Coverage: > 99%
System Availability: 99.999%
4.3 Environmental
Operating Temperature: 0°C to +60°C
Storage Temperature: −40°C to +85°C
Humidity: 5%–95% non‑condensing
Vibration: 5–200 Hz, 1g
4.4 Power
Backplane: 5 VDC / 1.2 A
4.5 Physical
Dimensions: 133 mm × 114 mm × 32 mm (5.25” × 4.50” × 1.25”)
Weight: ~0.38 kg
Mounting: Trident baseplate, 19” rack
5. Functional Overview
TMR Analog Measurement
Three independent A/D converters per channel; 2oo3 voted result.
Signal Conditioning
Over‑voltage, over‑current, and ESD protection on each input.
Diagnostics & Alarms
Open/short circuit, out‑of‑range, sensor drift, module temperature fault; reported via TriStation.
SOE Logging
Time‑stamps fault/state changes (≤ 40 ms).
6. LED Indicators
PWR (Green): Module power OK
RUN (Green): Active, communicating
FAULT (Red): Channel/module fault
CH 1–8 (Yellow): Channel active / fault
7. Installation & Configuration
Insert 2551 into an empty Trident baseplate slot.
Connect field transmitters/sensors to the AI terminal base.
Use TriStation 1131 to:
Set input type (4–20 mA / 0–10 VDC)
Configure range, scaling, and filtering
Enable diagnostics (open/short, out‑of‑range)
Verify: PWR + RUN green, no FAULT red.
8. Typical Applications
Pressure, temperature, flow, level transmitters (4–20 mA)
0–10 VDC analog sensors
ESD/BMS process variable monitoring
SIL 3 safety loops in oil & gas, power, chemical
Fire & gas system analog sensors
9. Maintenance
Hot‑swap faulty 2551 without shutdown.
Inspect field wiring and terminal base connections.
Review fault/SOE logs via TriStation.
10. Ordering Information
Model: 2551
Description: Triconex Trident 8‑Channel TMR Analog Input Module (4–20 mA / 0–10 VDC, SIL 3)
Compatible with: Trident Chassis, 2101/3700A MP Modules, TriStation 1131
Get a Quote