1600071-001
May 18, 2026

1600071-001

TRICONEX 1600071‑001 Model Positioning Model: 1600071-001 (Original Factory Part Number) Brand: TRICONEX (Schneider Group, formerly Invensys) Type: Tricon TMR SIS System Main Controller Module (CPU/MPM) Purpose: Core computing and safety logic execution unit of SIS/ESD system, responsible for I/O management, interlock operation, communication and fault diagnosis Status: Original, mainstream model, SIL3 safety certification, long-term supply

Description

Core parameters

Architecture: TMR triple redundancy (three-out-of-two voting), three-channel independent operation voting

Processor: 64-bit CPU, high real-time performance, high throughput

Safety level: SIL3 (IEC 61508), meeting safety requirements for high-risk scenarios

Memory: High-speed DRAM + redundant NVRAM (battery backup)

I/O capacity: Maximum support for 10 expansion racks, 5000 points of I/O

Event recording: 1ms resolution SOE, precise fault traceability

Communication interfaces:

Redundant Ethernet (FTE): supports Modbus TCP, Tricon proprietary protocol

Internal system bus: connects I/O modules and expansion racks

Operating voltage: 24VDC ±20% (19.2–30VDC)

Power consumption: approximately 8W

Operating temperature: -40°C ~ +70°C

Certifications: SIL3, CE, UL, FM, ATEX Zone 2

Installation: Tricon host slot (standard 19" rack)

Weight: approximately 1.5kg

Features and benefits

TMR triple redundancy safety architecture: three-channel independent sampling, computing, and voting, no single point failure, SIL3 safety level

Core safety logic operations: execute ESD emergency stop, F&G fire and gas interlock, BMS boiler protection, etc. safety programs

Full system diagnosis + hot swapping: real-time diagnosis of CPU, I/O, communication, power failures, supports online replacement, non-stop maintenance

High-speed I/O and SOE: millisecond response, 1ms event sequence recording, meeting accident traceability and compliance requirements

Multi-protocol redundant communication: dual network redundancy, seamless connection to DCS, HMI, upper computer and third-party safety systems

Typical applications

ESD emergency stop system: key process interlocks in chemical, oil and gas, and refining and chemical plants, automatic shutdown in case of over-limit

F&G fire and gas system: processing and alarming interlocks for combustible/toxic gas, flame detection signals

BMS boiler management system: safety monitoring and protection of steam pressure, water level, furnace temperature

SIL3-level safety control: core controller for safety instrument systems in high-risk scenarios such as power, metallurgy, and rail transportation

Reference of the same series

1600071‑001: Tricon TMR main controller (this model)

4351A/B: Tricon redundant communication module

0905‑148‑6921: 16-channel analog input (AI)

0923‑141‑6957: TMR Ethernet communication module


Get a Quote