Honeywell 51201420008 Product Detailed Description
Description

Honeywell 51201420008 Product Detailed Description
Model: 51201420008 (Full model: 51201420-008)
Brand: Honeywell
Product Type: DCS System I/O Connection Cable (FTA I/O Cable)
Series: TDC3000 / TPS / Experion PKS Distributed Control System
I. Product Overview
51201420008 is a I/O signal connection cable specifically designed by Honeywell for the TDC3000, TPS, and Experion PKS series DCS control systems. It is used for signal transmission and electrical connection between the FTA (Field Termination Assembly) and I/O modules in the system. As a key signal link of the control system, its function is to precisely and stably transmit analog/digital signals between the field instruments and control modules, ensuring the reliable operation of the entire industrial process control system.
II. Core Specification Parameters
Product Name: MU-KFTA08 FTA I/O Cable
Cable Length: 8 meters (26.2 feet)
Adapter Interfaces: Both ends are D-Sub high-density connectors (male/female pairs)
Connection Targets: FTA field terminal board ↔ I/O control card (such as APM, HPM I/O module)
Cable Structure: Multi-core twisted shielded cable, anti-electromagnetic interference (EMI/RFI)
Signal Types: Supports **analog (AI/AO), digital (DI/DO)** signal transmission
Insulation Material: Flame-retardant PVC, compliant with industrial safety standards
Shielding Layer: Overall aluminum foil + copper mesh double-layer shielding, grounding design
Operating Temperature: -40℃ ~ +75℃
Protection Characteristics: Oil-resistant, acid and alkali resistant, anti-aging, suitable for industrial site environments
III. Functions and Features
High-reliability signal transmission
Twisted shielded structure, effectively suppressing industrial site electromagnetic interference, ensuring signal integrity
Low signal attenuation, low crosstalk, ensuring the accuracy of analog signal and the stability of digital signal
Compliant with Honeywell DCS system electrical specifications, no signal distortion, no communication failures
Industrial-grade durability
High-flexibility industrial cable, resistant to bending, dragging, and oil stains
Wide temperature operating range, suitable for extreme industrial environments (high-temperature workshops, low-temperature storage areas)
Gold-plated contacts on connectors, anti-oxidation, low contact resistance, long insertion and removal life
Standardized design
Plug-and-play, strictly matching Honeywell FTA and I/O module interface definitions
8-meter standard length, meeting standard wiring requirements for cabinets / inter-cabinets
Supports hot swapping (subject to system conditions), maintenance is convenient
System compatibility
Fully compatible: TDC3000, TPS, Experion PKS system
Compatible FTA models: MU-KFTAxx series, K2Lxx, K2Txx, etc. field terminal components
Compatible I/O modules: APM, HPM, PM, etc. I/O cards
IV. Typical Application Scenarios
Petroleum and Chemical Industry: Refining plants, ethylene plants, chemical synthesis processes DCS control
Electric Power and Energy: Thermal power plants, nuclear power plants, substation automation control systems
Metallurgy and Mining: Steel smelting, non-ferrous metal processing process control
Pharmaceuticals and Food: Pharmaceutical reactions, food processing automated production lines
Paper and Printing: Paper machines, coating machines, printing machines DCS control systems
Building Automation: Large-scale building HVAC, air conditioning, water supply and drainage automation systems
V. Installation and Usage Specifications Installation method
Run along the cable trough / frame, keeping away from strong power cables (≥ 30cm spacing)
The bending radius should be ≥ 10 times the diameter of the cable, and avoid excessive bending to damage the core wires
The shielding layer should be reliably grounded at one end (recommended to ground on the controller side)
Wiring specification
Connector tightening torque: 0.5 - 0.8 N·m
Ensure that the plug is fully inserted, the latch is in place, without looseness or false connection
The cable identification is clear, marking the I/O channel number, signal type, and FTA position
Maintenance points
Regularly check if the connectors are oxidized, loose, or corroded
Test the signal transmission quality, without interference, no packet loss, no drift
Replace damaged or aged cables immediately to avoid system failures
Six. Model Coding Rules
51201420: Honeywell DCS Cable Series Basic Code
008: Cable Length Code (8 meters)
Length models of the same series:
51201420-002: 2 meters
51201420-005: 5 meters
51201420-008: 8 meters (this model)
51201420-010: 10 meters
51201420-015: 15 meters
Seven. Product Certification and Compliance
Compliant with IEC 61010 Industrial Safety Standard
Passed CE, UL, CSA Certification
Compliant with RoHS Environmental Directive (lead-free, mercury-free, cadmium-free)
Honeywell Original 12-month Warranty
Eight. Order Information
Order Model: 51201420008 (51201420-008)
Product Name: FTA I/O Connection Cable, 8 meters
Packaging Specification: Single independent packaging, including certificate of conformity and label
Alternative Model: MU-KFTA08 (fully equivalent)
Get a Quote