Model 6200080 is an industrial inductive proximity sensor. It is designed for non-contact detection of metal objects, widely applied in automatic machinery, production line position locating, limit stroke control, conveyor systems and mechanical signal feedback. With IP67 dustproof and waterproof grade, strong anti-interference and stable performance, it can work continuously in harsh industrial environments.

Description

霍尼韦尔13.jpg

2. Main Features

  • Model: 6200080

  • Working principle: Inductive magnetic induction

  • Detection object: All metal materials

  • Supply voltage: 10–30 V DC

  • Output type: 3-wire DC

  • Max load current: ≤ 200 mA

  • Protection class: IP67 dustproof & waterproof

  • Operating temperature: -25 °C ~ +70 °C

  • Built-in reverse polarity, overvoltage and short-circuit protection

  • Vibration resistant, shockproof and long service life

3. Safety Precautions

  • Cut off power before installation and wiring.

  • Do not exceed rated voltage 10–30 V DC.

  • Strictly prohibit reverse power connection to avoid burnout.

  • Keep away from high-power motors, transformers and strong magnetic interference.

  • Do not disassemble or modify the sensor structure privately.

  • Avoid mechanical impact, oil corrosion and long-term damp immersion.

4. Installation Instructions

  1. Fix the sensor with lock nut or mounting bracket.

  2. Keep proper effective sensing distance from metal target.

  3. Install perpendicular to the detected surface for best sensitivity.

  4. Do not place extra metal parts around the sensing head.

  5. Arrange cable routing properly, avoid sharp bending and strong pulling.

5. Wiring Definition

  • Brown  : DC +10~30 V Power

  • Blue   : DC 0 V Ground

  • Black  : Signal output

  • Shield : Ground only at controller side

6. Operating Instructions

  1. Wire strictly according to standard definition.

  2. Power on, the sensor enters standby state.

  3. When metal enters effective detection range, indicator lights up and output acts.

  4. When metal leaves detection area, output resets and indicator turns off.

  5. Can be directly connected to PLC, relay and automation controller input terminals.

7. Troubleshooting

  • No indicator light: Check power supply and wiring connection.

  • Always output signal: Metal too close or surrounding metal interference.

  • Signal unstable flickering: Loose wiring, vibration or power fluctuation.

  • Indicator on but no output: Signal wire broken or load damaged.

8. Maintenance

  • Clean dust and iron debris on sensing surface regularly.

  • Periodically check mounting tightness and cable wear condition.

  • Avoid long-term high temperature and corrosive gas environment.

  • Replace sensor timely if shell crack or cable aging occurs.