A06B-6077-H106
May 13, 2026

A06B-6077-H106

FANUC A06B-6077-H106 Alpha Power Supply Module (PSM-5.5) General Description The A06B-6077-H106 is a high-performance Alpha series power supply module (PSM-5.5) manufactured by FANUC. It converts three-phase AC input into regulated DC voltage to supply power to FANUC α/αi series servo amplifiers and spindle modules. Designed for CNC machine tools and automation systems, it ensures stable, efficient power conversion for reliable motion control. Widely used with FANUC 16i/18i/21i series CNC controllers, it supports both new installations and maintenance replacements. Product Specifications Part Number: A06B-6077-H106 Type: Alpha Power Supply Module (PSM-5.5) Input: 200–230 VAC, 3-phase, 50/60 Hz, 26 A @ 200 V Output: 283–325 VDC, 6.8 kW Cooling: Forced air cooling (built-in fan) Dimensions: 385 mm × 90 mm × 307 mm Weight: Approx. 14.0 lbs (6.35 kg) Compatibility: FANUC α/αi servo/spindle modules; 16i/18i/21i CNC controllers Key Features High-Efficiency Conversion: Converts AC to DC with high efficiency, reducing energy loss and heat generation. Compact & Rugged Design: Space-saving vertical mounting; heavy-duty housing withstands industrial vibration and temperature fluctuations. Integrated Protection: Built-in overload, overvoltage, undervoltage, overcurrent, and overtemperature protection with LED alarm indicators. Regenerative Capability: Supports regenerative braking to recycle energy during motor deceleration, improving system efficiency. Easy Integration: Plug-and-play compatibility with FANUC Alpha series drives; simple wiring and configuration. Application Scope CNC Machine Tools: Machining centers, lathes, grinders, and milling machines with FANUC α/αi servo/spindle systems. FANUC CNC Controllers: 16iTA, 16iMA, 18iTA, 18iMA, 21iTA, 21iMA series. Industrial Automation: High-precision positioning systems, multi-axis synchronization platforms. Retrofit Projects: Replacement for older FANUC power supply modules (e.g., A06B-6077 series). Installation Instructions Pre-Installation: Power off the CNC system and disconnect all cables. Mount the module vertically in a ventilated electrical cabinet; allow 100 mm clearance top/bottom for cooling airflow. Wiring: Connect three-phase AC power to L1/L2/L3 terminals; link DC output to servo/spindle amplifiers. Use shielded cables for all power lines; tighten terminals to 1.2–1.5 N·m. Grounding: Ensure reliable PE (protective earth) connection to reduce EMI and electric shock risk. Configuration: Power on the system; set power supply parameters via the CNC controller (e.g., voltage rating, current limit). Testing: Perform a no-load trial run; verify DC output voltage and check for abnormal noise or overheating. Wiring Requirements Power Cables: 2.5–4 mm² copper wires for AC input; 4–6 mm² for DC output (per current rating). Signal Cables: Separate high-power and signal cables by ≥30 cm to avoid crosstalk. Cooling: Keep fan vents clear of dust and obstructions; ensure unimpeded airflow. Terminals: Torque all screws to specification; inspect for loose wires or cold joints. Working Environment Operating Temperature: 0°C to +55°C Storage Temperature: -20°C to +70°C Humidity: ≤85% RH (non-condensing) Vibration: ≤0.5 g (10–100 Hz); avoid direct impact Atmosphere: No corrosive gases, oil mist, or conductive dust; keep cabinet dry and ventilated. Maintenance Instructions Daily Check: Verify LED status (normal: POWER green, ALARM off); check for abnormal noise or overheating. Monthly Maintenance: Power off and clean dust from cooling fans/vents with a dry brush; check cable connections for tightness. Quarterly Inspection: Test DC output voltage; inspect terminals for oxidation or corrosion. Annual Service: Replace aging cooling fans; back up system parameters; perform full-load operation test. Alarm Codes & Troubleshooting AL-01: Overcurrent in main power module → Check for short circuits in wiring or loads. AL-02: Cooling fan stopped → Replace fan or clear obstructions. AL-03: Heat sink overtemperature → Clean vents; reduce load. AL-04: DC voltage drop → Check input power; verify load conditions. AL-05: Main capacitor recharge failure → Replace capacitor or check charging circuit. AL-06: Input power abnormal → Verify three-phase voltage balance. AL-07: DC overvoltage → Check regenerative circuit or reduce deceleration rate. Safety Precautions Qualified Personnel: Only certified electrical technicians may install, wire, or maintain the module. Power Safety: Never connect/disconnect cables while powered on; wait 10 minutes after power-off for capacitor discharge. Fault Handling: If an alarm triggers, power off immediately; inspect the system before restarting. Modification: Do not alter internal circuits or use non-FANUC replacement parts; voids warranty and risks safety hazards.

Description

发那科5.jpg


Get a Quote