A06B-6050-K120
Description

Product Characteristics
Type: D-Sub 15pin (DB15) right-angle signal connector
Housing: High-strength flame-retardant engineering plastic
Contacts: Tin-plated copper alloy, oxidation-resistant and wear-resistant
Shielding: Integrated metal shield shell for EMI/RFI suppression
Locking: Built-in positive-locking mechanism to prevent vibration-induced loosening
Weight: Approx. 0.08 kg
Status: Discontinued by FANUC; available as new old stock or refurbished units
Temperature Range: 0°C to +40°C (operating); -20°C to +60°C (storage)
Application Scope
Compatible Drives: FANUC A06B-6050 series servo amplifiers and velocity control units
Compatible CNC Systems: FANUC Series 6, 10, 11, and other legacy systems
Machines: CNC lathes, milling machines, machining centers, and grinding machines
Signals Handled: Encoder position feedback, 0–10V analog speed command, servo enable, alarm output, and over-limit signals
Retrofit: Ideal for old machine tool renovation and servo system replacement projects
Difference from A06B-6050-K119
K119: Straight-type DB15 connector, for standard inline wiring; suitable for straight-through cable routing
K120: Right-angle DB15 connector, for corner wiring in cramped cabinets; saves space and reduces cable bending stress; enhanced shielding for high-noise environments
Installation Instructions
Perform all installation and wiring with all power disconnected to avoid electric shock or component damage.
Strip the shielded cable per standard wire gauge, preserving the inner core integrity.
Crimp or solder conductors to connector pins per FANUC official pinout; ensure firm contact with no cold joints.
Insert crimped pins into the housing until positively locked.
Align the right-angle connector with the servo amplifier port, insert smoothly, and tighten the locking screw.
Allow adequate cable slack to avoid tension at the connector; avoid sharp bends.
Wiring Requirements
Use FANUC-certified shielded signal cables only.
Route signal cables separately from high-power cables; maintain minimum 15 mm spacing to reduce crosstalk.
Ground the cable shield at both ends per specifications to maximize noise immunity.
Strictly follow FANUC’s official pin assignment; do not alter wiring order.
Keep contacts clean and dry; prevent oil contamination and moisture ingress.
Working Environment
Operating Temperature: 0°C to +40°C
Storage Temperature: -20°C to +60°C
Relative Humidity: ≤80% (non-condensing)
Environment: Avoid corrosive gases, oil mist, conductive dust, and excessive vibration.
Location: Do not install in direct sunlight or near high-temperature heat sources.
Maintenance Instructions
Periodically (quarterly) power off and inspect connector seating and lock integrity.
Clean dust and oil with a dry soft cloth; keep contact surfaces clean and dry.
Check cables for aging, sheath cracks, or contact oxidation; replace if abnormal.
Minimize frequent unplugging to prevent pin deformation and lock failure.
Do not disassemble the connector housing; internal damage will void shielding and electrical performance.
Safety Precautions
Installation, wiring, and removal must be performed by qualified electrical personnel.
Never hot-plug the connector; signal transients may damage the servo unit or CNC system.
Ensure reliable system grounding to minimize EMI and prevent electric shock.
Do not modify the connector structure or extend signal cables without official approval.
Keep the connector away from flammable materials and humid, high-temperature environments to ensure long-term safe operation.