DC162/IP20/53151
1. General Information
Part Number: DC162/IP20/53151 (also DC 162/IP20/53151/02 /04)
Manufacturer: KEBA Industrial Automation
Type: PLC breakout / I/O interface board (KePlast / injection molding / machine control)
Protection: IP20 (cabinet mounting)
Weight: ~0.6 kg
Form: DIN-rail / chassis mount, with screw terminal blocks
2. Electrical Ratings
Supply Voltage: 24 VDC ±10% (19.2–30 VDC)
Current Consumption: ≤1.2 A
Protection: Overvoltage, overcurrent, short‑circuit, reverse polarity, EMC filtering
3. I/O Configuration (DC162)
Digital Inputs: 16 × 24 VDC (sink/source)
Digital Outputs: 8 × 24 VDC / 0.5 A (transistor)
Analog Inputs: 4 × (0–10 V / 4–20 mA), 12‑bit
Analog Outputs: 2 × 0–10 V, 12‑bit
Encoder: 1 × incremental (A/B/Z, 5 V)
4. Communication & Interfaces
K‑Bus: KEBA backplane bus (to CU312/CU313 CPU)
RS‑232: 1 × DB9 (service/debug)
Status LEDs: PWR, RUN, ERR, channel status
5. Environmental
Operating Temp: 0 °C to +55 °C
Storage Temp: −40 °C to +85 °C
Humidity: 5%–95% RH, non‑condensing
6. Mechanical
Dimensions (H×W×D): approx. 160 × 100 × 35 mm
Mounting: DIN‑rail or direct chassis mounting
Terminals: Screw terminals for field wiring
7. Features
Industrial I/O breakout for KEBA control systems
Isolated digital I/O for noise immunity
Precision analog front‑end for sensors/transducers
Real‑time motion/process control synchronization
Compatible with KePlast, KeMotion, KeControl platforms
8. Installation
Disconnect power before installation/removal.
Mount on DIN‑rail or chassis; secure firmly.
Use shielded cables for analog/encoder signals.
Keep cabinet well ventilated; avoid direct heat.
Tighten all terminals; inspect contacts periodically.
9. Safety
For qualified personnel only (installation, config, service).
Operate only within rated voltage/temperature range.
Do not modify the board; voids warranty.
Disconnect power before wiring or maintenance.