140DAO84220C
May 16, 2026

140DAO84220C

140DAO84220C Modicon Quantum AC Discrete Output Module 140DAO84220C Modicon Quantum AC Discrete Output Module 16 Outputs, 20–56 V AC, 47–63 Hz, Triac, Conformal Coated, Fused, With Diagnostic English Specification Manual (Full Text) 1. General Description 140DAO84220C is a 1‑slot conformal coated low‑voltage AC discrete output module (triac, 4×4 grouped, fused, with diagnostics) for Schneider Electric Modicon Quantum PLC. It provides 16 AC solid‑state (triac) output channels, arranged as: Outputs: 4 groups × 4 channels (4×4 grouping, group‑to‑group isolation) Designed for low‑voltage AC (24/48 V AC) in harsh/humid/corrosive environments, requiring grouped isolation, on‑board fusing, and fault diagnostics. Manufacturer: Schneider Electric Series: Modicon Quantum (140 Series) Module Type: AC Discrete Output Module, Triac, 16‑Ch (4×4), Conformal Coated, Fused, With Diagnostic Total Outputs: 16 points (4 groups × 4 ch) Output Grouping: 4 groups × 4 ch (group isolated, common per group) Form Factor: 1 slot, hot‑swappable Coating: Conformal coated (Humiseal 1A33, IPC‑CC‑830 qualified) Weight: ~0.45 kg Key Feature: 16×Triac Out, 20–56V AC, 47–63Hz, 4×4 Group Isolation, Conformal Coated, Fused, With Diagnostic Application: 24/48V AC contactors, solenoids, small motors; offshore, chemical, pulp & paper, high humidity, salt mist, corrosive atmosphere 2. Electrical Specifications Outputs (16 × Triac, 20–56 V AC, 4×4 Groups) Output Type: Solid‑state (triac), zero‑crossing Operating Voltage: 20–56 V AC Nominal Voltage: 24 / 48 V AC Frequency: 47–63 Hz Load Current (per channel): 20–56 V AC: 4 A RMS max Total Module Current: 16 A RMS max (continuous) Surge Current (per channel): 45 A (1 cycle) 30 A (3 cycles) 25 A (10 cycles) Off‑State Leakage Current: < 2 mA RMS On‑State Voltage Drop: ≤ 1.5 V RMS dv/dt Rating: 400 V/μs Isolation: 2500 Vrms, 1 min (group‑to‑group & group‑to‑bus) Absolute Maximum Output: 60 Vrms (continuous) Backplane & Power Backplane Current: 350 mA Power Dissipation: ~8.0 W max Internal Power: Powered by Quantum backplane Fusing & Diagnostics Fused: 5 A per group (on‑board, replaceable) Diagnostics: Blown fuse / loss of field power Fault LED: Red “F” (fuse/field power fault) 3. I/O & LED Indicators (Front) OUT0 … OUT15 (Green LEDs) – Individual output status (ON = lit) ACTIVE (Green LED) – Bus communication OK F (Red LED) – Fault (blown fuse / field power loss) 4. Environmental Specifications (Coating Enhanced) Operating Temperature: 0 °C … +60 °C Storage Temperature: −40 °C … +85 °C Relative Humidity: 5% … 95% non‑condensing Altitude: ≤ 2,000 m (standard); up to 5,000 m derated ESD: 4 kV contact / 8 kV air EMI: 10 V/m (80–2000 MHz) Protection Class: IP20 Coating Protection: Resists moisture, dust, salt mist, and common industrial contaminants 5. Physical & Mechanical Dimensions (W × H × D): 35 × 122 × 52 mm (1 slot) Mounting: Any single slot, hot‑swap compatible Wiring: Screw terminals (field side) Output Grouping: 4 groups × 4 ch (common per group) Field Wire Size: 0.5 … 2.5 mm² (20–14 AWG) 6. Wiring & Connection Outputs Common: Common per group (4 groups) Output: Switch 20–56 V AC between common and output terminal (per channel) Fuse: 5 A / group (internal, replaceable) Shielding: Recommended for long cables; ground at one end only Polarity: AC, no polarity sensitivity 7. Software Configuration Supported software: Unity Pro (recommended) Concept v2.2+ ProWORX 32 Configuration: Add 140DAO84220C (1 slot) to I/O map Default output address: %Q0 … %Q15 (1 word) Enable fault diagnostics (fuse/field power) Download to CPU 8. Troubleshooting All OUT LEDs OFF: Check backplane, module seating, or ACTIVE LED ACTIVE OFF: Module not recognized; reseat or check backplane F (Red) ON: Blown group fuse or loss of field power OUT LED ON but load not energized: Check field wiring, load, or group fuse Erratic Operation: Poor grounding, noise, or overvoltage Coating Note: Do not apply additional conformal coating; factory coating is sufficient 9. Certifications CE (EN 55011, EN 61131‑2) UL 508 / CSA C22.2 No. 142 CUL, FM Class I Div 2 RoHS compliant Coating: IPC‑CC‑830 qualified 10. Ordering Information 140DAO84220: Standard non‑coated, 16×Triac 20–56V AC, 4×4 Group, Fused / With Diagnostic (general environment) 140DAO84220C: Conformal coated, 16×Triac 20–56V AC, 4×4 Group, Fused / With Diagnostic (harsh environment)

Description

Get a Quote