140CPS41400
May 16, 2026

140CPS41400

Schneider Electric 140CPS41400 Modicon Quantum – 5.1 VDC Backplane Power Supply (8 A Summable, 48–60 VDC Input, Non‑Coated, Alarm Contact)

Description

施耐德5.jpg

Schneider Electric

140CPS41400

Modicon Quantum – 5.1 VDC Backplane Power Supply

(8 A Summable, 48–60 VDC Input, Non‑Coated, Alarm Contact)

1. General Information

  • Manufacturer: Schneider Electric

  • Part Number: 140CPS41400

  • Series: Modicon Quantum PLC

  • Type: Rack‑mount backplane power supply (summable only, non‑redundant)

  • Input: 48–60 VDC (nominal 48 VDC)

  • Output: 5.1 VDC (logic power for Quantum backplane)

  • Application: Quantum racks with 48V DC plant supply; parallelable (up to 4 units → 32 A total)

  • Coating: Non‑coated (standard)

  • Key Difference vs 140CPS21400: 48V input (21400 = 24V)

  • Key Difference vs 140CPS42400: 41400 = summable only; 42400 = redundant + summable


2. Electrical Specifications

Input (DC)

  • Voltage: 48–60 VDC (wide range)

  • Input Current: 3.8 A max

  • Inrush Current:

    • 14 A @ 40 VDC

    • 25 A @ 48 VDC

  • Hold‑up Time: 13 ms max @ 48 VDC

  • External Fuse: 2 A time‑lag (slow‑blow)

Output

  • Voltage: 5.1 VDC ±1% (regulated)

  • Current (@60°C): 0.5–8 A continuous, summable

  • Total Parallel Current: Up to 32 A (4 × 8 A modules)

  • Ripple & Noise: < 50 mVpp typical

  • Protection: OVP / OLP / SCP / thermal shutdown (all internal)

  • Power Dissipation: 15.6 W

  • Efficiency: ≥ 88% typical

Signaling & Alarm

  • Local Indication: Green “PWR OK” LED

  • Alarm Contact: 1 × NC (Normally Closed), 6 A / 220 VAC (fault alarm)


3. Environmental & Mechanical

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: −40 °C to +85 °C

  • Relative Humidity: 95% RH max, non‑condensing

  • Altitude: Up to 5,000 m

  • Protection Class: IP20 (indoor use)

  • Mounting: 1 slot in Quantum backplane

  • Weight: Approx. 0.65–0.80 kg

  • Hot‑swappable: Yes


4. Key Features

  1. 48–60 VDC wide‑range input: for 48V industrial systems.

  2. 8A high‑current 5.1 VDC output: for medium/large Quantum racks.

  3. Summable (parallelable): up to 4 units → 32 A total.

  4. NC alarm contact: remote fault monitoring (6 A / 220 VAC).

  5. Green “PWR OK” LED: local status.

  6. Full protection: OVP / OLP / SCP / thermal shutdown.

  7. Hot‑swappable: replace without rack shutdown.


5. Certifications

  • CE

  • UL 508

  • CUL / CSA C22.2 No 142

  • FM Class 1 Div 2

  • RoHS compliant


6. Ordering Notes

  • 140CPS41400: 48–60 VDC, 8 A summable, non‑coated, NC alarm.

  • 140CPS41400C: Conformal coated version (harsh environment).

  • Compare to 140CPS21400: 41400 = 48V input; 21400 = 24V input.

  • Compare to 140CPS42400: 41400 = summable only; 42400 = redundant + summable.


Get a Quote