PCI-6520
Description
Model: PCI‑6520
Part Number: 779443‑01
Brand: National Instruments (NI)
Series: 652x Industrial Isolated DIO
Bus: PCI (5 V, half‑length)
Connector: 1 × 37‑pin D‑Sub (keyed)
Isolation: Channel‑to‑channel optically isolated (8 DI); relay‑isolated (8 DO)
Driver: NI‑DAQmx
Operating Temp: 0 ~ 55 °C
Features: ±30 VDI, 60 V / 2 A relay DO, channel‑to‑channel isolation, watchdog, programmable power‑on, low cost
I. Digital Inputs (DI) – 8 ch, isolated, sink/source
Channels: 8 channel‑to‑channel optically isolated digital inputs
Voltage Range: ±30 VDC
Logic Thresholds: Low ≤ +4 V, High ≥ +11 V
Input Type: sink or source configurable (24 V logic)
Filtering: programmable debounce filters per channel
Functions: change detection, event counting, status monitoring
II. Relay Outputs (DO) – 8 ch, non‑latching mechanical relay
Channels: 8 non‑latching mechanical relay outputs
Switching Voltage: ±60 VDC / 30 Vrms max
Switching Current: 2 A / channel max
Switching Power: 60 W / 60 VA max
On‑Resistance: < 100 mΩ (typical)
Power‑On State: programmable (open / closed)
Life Cycle: 100,000 operations (resistive load)
Functions: load switching, emergency cut‑off, high‑voltage control
III. Industrial Features
Watchdog Timer: 1–65535 ms; fault → safe state (open/closed)
Programmable Power‑On: prevents unexpected actuation
Channel‑to‑Channel Isolation: each DI isolated; relays isolate DO from system
High CMR: robust for motors, inverters, relays
Keyed Connector: prevents miswiring, enhances safety
IV. Physical & Environmental
Size: half‑length PCI, ~12.4 × 12.6 × 2.2 cm
Weight: ~0.15 kg
Temperature: 0 ~ 55 °C (oper), −20 ~ 70 °C (storage)
Humidity: 10%–90%, non‑condensing
Isolation Voltage: ≥ 500 Vrms (DI channels to system ground)
Power: +5 V @ ~200 mA; +3.3 V @ ~300 mA
V. Wiring Highlights
DI (sink/source): sensor to +24 V or GND; threshold +4 V low / +11 V high
Relay DO: load between relay common (COM) and normally open (NO) / normally closed (NC); max 60 V / 2 A
Inductive loads: add 1N4007 freewheeling diode across coil
Shielding: shield to isolated field ground, not system ground
VI. Core Advantages & Applications
8 channel‑to‑channel isolated DI (±30 V) + 8 relay DO (60 V / 2 A)
True channel‑to‑channel isolation, mechanical relays, watchdog, programmable power‑on, NI‑DAQmx
Ideal for 24 V sensor monitoring + high‑voltage/high‑current load switching, industrial control panels, test stands, safety interlocks










Get a Quote