cFP-SG-140
May 15, 2026

cFP-SG-140

cFP‑SG‑140 is an 8‑channel, 16‑bit strain/bridge input module for Compact FieldPoint, designed for direct measurement of full‑bridge, half‑bridge strain gauges and bridge‑based transducers (load cells, force/torque sensors). It provides programmable excitation, filtering, and isolation. EOL / Discontinued; recommended replacement: NI‑9237 (4‑ch, 50 kS/s/channel, C‑Series).

Description

cFP-SG-140.jpg

cFP‑SG‑140

National Instruments Compact FieldPoint Strain/Bridge Input Module

General Description

cFP‑SG‑140 is an 8‑channel, 16‑bit strain/bridge input module for Compact FieldPoint, designed for direct measurement of full‑bridge, half‑bridge strain gauges and bridge‑based transducers (load cells, force/torque sensors). It provides programmable excitation, filtering, and isolation. EOL / Discontinued; recommended replacement: NI‑9237 (4‑ch, 50 kS/s/channel, C‑Series).

Part Number

  • Model: cFP‑SG‑140

  • NI PN: 777318‑140

Key Specifications

  • Channels: 8 differential strain/bridge inputs

  • Sensor Types: Full‑bridge, half‑bridge strain gauges; quarter‑bridge (external completion)

  • Resolution: 16‑bit delta‑sigma ADC

  • Input Ranges: ±3.5, ±7.5, ±30, ±60 mV/V (with overranging)

  • Excitation (per channel, programmable): 2.5 V, 5 V, 10 V DC

  • Input Impedance: 20 MΩ

  • Filters (software‑selectable): 15 Hz, 60 Hz, 240 Hz (low‑pass)

  • Update Rate: 0.87–1.11 Hz per channel; 0.9–1.15 s all‑channels

  • Isolation: 2,300 Vrms transient (bank‑to‑backplane); 250 Vrms continuous

  • Connectors: 37‑pin D‑Sub (cFP‑CB‑1/CB‑3 terminal bases)

  • Indicators: POWER, READY (green); 8 × channel overcurrent (red)

  • Power Consumption: ~400 mW (from backplane)

  • Operating Temperature: ‑40 °C to +70 °C

  • Storage Temperature: ‑55 °C to +85 °C

  • Humidity: 10–90% RH, non‑condensing

  • Certifications: CE, UL, CSA, FM (hazardous locations)

  • Calibration: NIST‑traceable certificate included

  • Weight: ~105 g (3.7 oz)

Main Features

  • 8‑Channel Strain Measurement: Supports full/half‑bridge strain gauges and load cells with programmable excitation.

  • High Resolution & Low Noise: 16‑bit ADC and selectable low‑pass filters ensure precise, stable readings.

  • Flexible Input Ranges: Four mV/V ranges with overranging accommodate various sensor sensitivities.

  • Industrial Isolation: 2,300 Vrms transient isolation protects against ground loops and voltage spikes.

  • HotPnP & Auto‑Scaling: Plug‑and‑play; auto‑linearizes bridge signals and outputs engineering units.

  • Self‑Diagnostics: Detects sensor faults (open/short) and overcurrent; reports via software/LEDs.

  • Robust Industrial Design: Wide temperature range, vibration tolerance, and safety certifications.

Applications

  • Structural health monitoring (bridges, buildings, towers)

  • Machine condition monitoring (vibration, stress, torque)

  • Industrial load/force/torque measurement (presses, cranes, test stands)

  • Aerospace/automotive component testing (strain, fatigue)

  • Legacy Compact FieldPoint system maintenance/expansion

Compatibility

  • Terminal Bases: cFP‑CB‑1 (36‑pin), cFP‑CB‑3 (18‑pin)

  • Backplanes: cFP‑BP‑x series

  • Controllers: All Compact FieldPoint network modules (e.g., cFP‑2000, cFP‑2010)


Get a Quote