CFP-AI-100
Description
I. Basic Information
Model: cFP-AI-100
Manufacturer: National Instruments (NI)
Series: Compact FieldPoint (cFP) I/O Module
Status: Obsolete (Out of Production), Recommended Replacement: NI-9207NI
Function: 8-channel general-purpose analog input, voltage/current signal acquisition
II. Core Hardware Specifications (Official)
Channels: 8 analog inputs (single-ended/differential selectable)
Resolution: 12-bit ADCNI
Update rate: 360 Hz (total)
Input range (software selectable, independent per channel):
Voltage: ±1 V, ±5 V, ±15 V, ±30 V, 0–1 V, 0–5 V, 0–15 V, 0–30 V
Current: 0–20 mA, 4–20 mA, ±20 mA (direct connection, no external shunt required)
Accuracy: ±(0.1% reading + 0.1% range)
Input impedance: Voltage 1 MΩ; Current 5 Ω
Common mode rejection: >90 dB
Isolation: Channels isolated from the backplane, no inter-channel isolation
Diagnosis: On-board overrange detection, open/closed circuit diagnosis (NI)
III. Environment and Mechanics
Operating temperature: -40 °C ~ +70 °C (industrial wide temperature range)
Humidity: 10%–90% RH, no condensation
Size: 92 × 60 × 20 mm
Weight: Approximately 50 g
Installation: cFP-BP-4 / BP-8 backplane, hot-swappable
IV. Typical Applications
4–20 mA Transmitter Acquisition: Pressure, Flow, Level, Temperature (with thermocouple/thermoresistor transmitters)
±10 V Sensor Signals: Acceleration, Strain, Displacement, Voltage-type Instruments
Industrial Process Monitoring: Production line parameters, environmental monitoring, energy data acquisition
Combined with cFP-2200/2210/2220: Form a complete real-time measurement and control system