cFP-2220
May 15, 2026

cFP-2220

I. Basic Information Model: cFP-2220 Part Number: 777317-2220 Series: Compact FieldPoint (cFP-22xx High-Performance Generation, Top-of-the-Line Configuration) Position: Multiple Serial Ports + Dual Network Redundancy, Large-scale Real-time System, High-end Gateway, Robust Control in Harsh Environments

Description

I. Basic Information

Model: cFP-2220

Part Number: 777317-2220

Series: Compact FieldPoint (cFP-22xx High-Performance Generation, Top-of-the-Line Configuration)

Position: Multiple Serial Ports + Dual Network Redundancy, Large-scale Real-time System, High-end Gateway, Robust Control in Harsh Environments

II. Hardware Specifications (22xx offers the most comprehensive interfaces and the strongest configuration)

Processor: 400 MHz MPC5200 real-time CPU (VxWorks) Memory:

DRAM: 256 MB (top-level configuration of 22xx series)

Non-volatile storage: 256 MB built-in (maximum of 22xx series)

Communication interface (key point!) :

Ethernet: 2 × 10/100 Mbps RJ45 (Redundant) (2200/2210 have only 1 port)

Serial Port: 3 × RS-232 (DB9) + 1 × RS-485 (22xx comes with RS-485 only)

I/O Expansion: cFP-BP-4 / BP-8 Backplane, up to 8 cFP I/O Modules

Storage / Expansion: CompactFlash Card + 1 × USB 2.0 Port

Power Supply: 11–30 VDC Industrial Wide Voltage, Dual Redundant Inputs

Temperature Range: -40 °C ~ +70 °C (Industrial Wide Temperature, Consistent throughout the series)

Size / Weight: 127 × 102 × 51 mm, Approximately 0.28 kg

III. Ultimate Comparison of cFP-2200 / 2210 / 2220 (One Look to Determine Model) Table

Project cFP-2200 cFP-2210 cFP-2220 (Top Configuration) CPU 400 MHz 400 MHz 400 MHz

DRAM 128 MB 256 MB 256 MB

Built-in storage: 128 MB, 128 MB, 256 MB

Ethernet: 1 port, 1 port, 2 ports (redundant)

Serial ports: 1×RS-232, 2×RS-232, 3×RS-232 + 1×RS-485 USB/CF 1×USB/CF 1×USB/CF 1×USB/CF

Typical Applications: High-speed basic control, dual serial port medium-sized system, multi-serial port + redundant network large system

IV. Software and Protocols (Uniform across the entire series)

Real-time system: LabVIEW Real-Time (VxWorks)

Programming: LabVIEW (recommended), LabWindows/CVI

Supported Protocols:

Ethernet: Modbus TCP, NI Real-Time Network, TCP/IP (dual network redundancy)

Serial Port: Modbus ASCII/RTU, Optomux (4 serial ports for independent communication)

V. The Most Suitable Application Scenarios of cFP-2220

Cluster networking of multi-serial port devices: 3×RS-232 connected to instruments/PLC/variable frequency drives + 1×RS-485 connected to bus sensors

Highly reliable dual Ethernet redundant system: Dual networks serve as backups, network failure does not interrupt (critical production lines / data acquisition)

Large-scale high-speed real-time control: 256 MB large memory running complex algorithms, multiple loop PID, high-speed data acquisition

High-density long-term data recording: 256 MB built-in + CF card expansion, ultra-large storage

Industrial-grade multi-protocol gateway: 4 serial ports ↔ dual Ethernet, multi-protocol conversion

NI11.jpg


Get a Quote