MVME162-520A
May 15, 2026

MVME162-520A

1. Official standard configuration (Motorola/Emerson) CPU: MC68040 32MHz (built-in FPU, MMU, 8KB unified cache) Form: 6U dual-height (2 slots) VME SBC (same as 510A/511A/512A/513A) DRAM: 8MB (non-parity check) SRAM: 512KB, battery backup (NVRAM) Flash: 1MB (board-level firmware / monitoring) I/O (standard): Ethernet: 10BASE-T (RJ45) + 10BASE2 (BNC), DMA No SCSI interface (key difference from 513A) Serial port: 2×RS-232/422/485 (software selectable) Parallel port: 1×Centronics RTC: Battery-backed real-time clock Expansion: 4×IP slots, no PMC slots VME: A16/A24/A32, D8/D16/D32, master / slave / system controller Temperature: Standard 0℃~+70℃; industrial wide temperature -40℃~+85℃

Description

1. Official standard configuration (Motorola/Emerson)

CPU: MC68040 32MHz (built-in FPU, MMU, 8KB unified cache)

Form: 6U dual-height (2 slots) VME SBC (same as 510A/511A/512A/513A)

DRAM: 8MB (non-parity check)

SRAM: 512KB, battery backup (NVRAM)

Flash: 1MB (board-level firmware / monitoring)

I/O (standard):

Ethernet: 10BASE-T (RJ45) + 10BASE2 (BNC), DMA

No SCSI interface (key difference from 513A)

Serial port: 2×RS-232/422/485 (software selectable)

Parallel port: 1×Centronics

RTC: Battery-backed real-time clock

Expansion: 4×IP slots, no PMC slots

VME: A16/A24/A32, D8/D16/D32, master / slave / system controller

Temperature: Standard 0℃~+70℃; industrial wide temperature -40℃~+85℃

II. Core Differences between 520A and 510A/513A/523A (Easy to Understand at a Glance) Table

Model CPU DRAM PMC SCSI Position

510A 32MHz 4MB ❌ ❌ Basic Entry-Level (Small Memory)

520A 32MHz 8MB ❌ ❌ High-End Basic Model (Recommended)

513A 32MHz 8MB ❌ ✅ Full Interface Main Model (With SCSI)

523A 32MHz 8MB ❌ ✅ Same as 513A, Batch Difference

Conclusion: 520A is the direct upgraded version of 510A, with doubled memory to 8MB, no PMC, no SCSI, and simplified interfaces. It is suitable for scenarios that do not require SCSI/fiber expansion, have a medium budget, and require dual high + 8MB + FPU.

III. Applicable Scenarios (520A is the most suitable)

✅ Replace the old 510A/512A: Direct compatibility, doubled memory, stronger performance

✅ Medium budget, need 8MB + dual high + FPU + basic network and serial ports

✅ No need for SCSI storage, no need for PMC high-speed expansion

✅ Industrial control, data acquisition, rail transportation, military: wide temperature range, high shock resistance, stable long-term supply

IV. Replacement Relationship (Fully Compatible)

Directly replace 510A: Function is the same, larger memory, stronger performance

Replace 512A: Memory 4MB → 8MB, no SCSI

Upgrade to 513A: Add SCSI interface, price increases

Upgrade to 511A: Add PMC slot, price increases

Upgrade to 530A: Memory expanded to 16MB, no PMC/SCSI