8BVP0440HW00.000-1 Detailed Product Description
Description

8BVP0440HW00.000-1 Detailed Product Description
1. Product Overview
2. Basic Information
Model: 8BVP0440HW00.000-1
B&R ID Code: 0xA074B& R Industrial Automation
Series: ACOPOSmulti
Type: Power Supply & Regeneration Module, Wall Mount
Mounting: Wall mountingB& R Industrial Automation
Expansion Slots: 2 (for ACOPOSmulti plug-in modules)B& R Industrial Automation
Key Features: Wide input voltage range, regenerative capability, integrated PFC, 2 trigger inputs, temperature sensor interfaceB& R Industrial Automation
Certifications: CE, UKCA, cULus (E225616), EAC, KCB& R Industrial Automation
3. Electrical Specifications
3.1 Mains Input Connection
Network Configurations: TT, TN-S, TN-C-SB& R Industrial Automation
Input Voltage: 3×220–480 VAC ±10%B& R Industrial Automation
Frequency: 50/60 Hz ±4%B& R Industrial Automation
Max Installed Load: 31.1 kWB& R Industrial Automation
Inrush Current (400 VAC): Max 67 AB& R Industrial Automation
Switch-On Interval: >300 sB& R Industrial Automation
Switching Frequency: 5 kHz (default); optional 10 kHzB& R Industrial Automation
Integrated Line Filter: No (does not meet EN 61800-3 Cat C3)B& R Industrial Automation
Integrated Regeneration Choke: NoB& R Industrial Automation
Power Factor Correction (PFC): YesB& R Industrial Automation
Line Fuse: Max 132 A (gG); Max 110 A (circuit breaker)B& R Industrial Automation
Terminal Cross-Section: 0.5–16 mm² (flexible); 20–6 AWG (UL/CSA)B& R Industrial Automation
3.2 DC Bus Connection
Nominal Voltage: 750 VDCB& R Industrial Automation
Continuous Power (Supply/Regeneration): 30 kWB& R Industrial Automation
Peak Power (Supply/Regeneration): 60 kWB& R Industrial Automation
DC Bus Capacitance: 825 µFB& R Industrial Automation
Power Derating:
Mains <400 VAC: 75 W/V × (400 V – Mains)B& R Industrial Automation
UDC <750 VDC: P × (1 – UDC/750)B& R Industrial Automation
5 kHz: 1.11 kW/K (starts at 40°C)B& R Industrial Automation
10 kHz: 0.35 kW/K (starts at -10°C)B& R Industrial Automation
Altitude >500 m: 3 kW per 1000 mB& R Industrial Automation
Protection: Overload protection (no short-circuit/ground fault protection)B& R Industrial Automation
3.3 24 VDC Auxiliary Supply
Input Voltage: 25 VDC ±1.6%B& R Industrial Automation
Input Capacitance: 4.7 µFB& R Industrial Automation
Max Power Consumption: 25 W + slot loads + 24V output + fan powerB& R Industrial Automation
Output Channels: 2B& R Industrial Automation
Output Regulation:
260–315 VDC bus: 25 VDC × (UDC/315)B& R Industrial Automation
315–800 VDC bus: 24 VDC ±6%B& R Industrial Automation
Fuse: 250 mA slow-blow electronic, auto-resetB& R Industrial Automation
3.4 Filter Fan Connection
Output Voltage: 24 VDC +5.8% / -0.1%B& R Industrial Automation
Continuous Current: 4.2 AB& R Industrial Automation
Max Overcurrent Limiting: 10 AB& R Industrial Automation
Protection: Short-circuit proof (no overload/open-circuit monitoring)B& R Industrial Automation
3.5 Trigger Inputs
Quantity: 2 channels (Sink type, isolated)B& R Industrial Automation
Nominal Voltage: 24 VDC (max 30 VDC)B& R Industrial Automation
Threshold: Low <5 V; High >15 VB& R Industrial Automation
Input Current: ~10 mA (nominal)B& R Industrial Automation
Delay: Rising 52 µs ±0.5 µs; Falling 53 µs ±0.5 µsB& R Industrial Automation
3.6 General Electrical Properties
Discharge Capacitance: 0.9 µFB& R Industrial Automation
Energy Efficiency: IE2 classificationB& R Industrial Automation
Standby Losses: 10.8 WB& R Industrial Automation
4. Mechanical Specifications
Dimensions (W × H × D): 106.5 mm × 317 mm × 263 mmB& R Industrial Automation
Weight: Approx. 5.5 kgB& R Industrial Automation
Protection Class: IP20 (EN 60529)B& R Industrial Automation
Pollution Degree: 2 (non-conductive)B& R Industrial Automation
Overvoltage Category: III (EN 61800-5-1)B& R Industrial Automation
5. Environmental Conditions
5.1 Temperature
Operating: 5–40°C (rated); up to 55°C (with derating)B& R Industrial Automation
Storage: −25–55°CB& R Industrial Automation
Transport: −25–70°CB& R Industrial Automation
5.2 Humidity
Operating: 5%–85% RH (non-condensing)B& R Industrial Automation
Storage: 5%–95% RH (non-condensing)B& R Industrial Automation
Transport: Max 95% RH at 40°C (non-condensing)B& R Industrial Automation
5.3 Mounting & Altitude
Allowed Orientation: Vertical hanging, horizontal face-upB& R Industrial Automation
Forbidden: Horizontal side mountingB& R Industrial Automation
Rated Altitude: 0–500 mB& R Industrial Automation
Max Altitude: 4000 m (with derating)B& R Industrial Automation
6. Interface & Terminal Assignment
X1 (Mains): L1/L2/L3/PE; power input connectionB& R Industrial Automation
X2 (24 VDC): Auxiliary power input and outputB& R Industrial Automation
X3 (Trigger): 2 trigger inputs for system controlB& R Industrial Automation
X4 (Fan): Filter fan power connectionB& R Industrial Automation
X5 (DC Bus): DC bus output to servo invertersB& R Industrial Automation
X6 (Slots): 2 expansion slots for plug-in modulesB& R Industrial Automation
7. LED Status Indicators
RDY (Green): Module ready; flashes on undervoltage/overtemperatureB& R Industrial Automation
RUN (Orange): DC bus active, power stage enabledB& R Industrial Automation
ERR (Red): Fault (overload, overtemp, regeneration error)B& R Industrial Automation
24V (Green): Auxiliary power supply normalB& R Industrial Automation
8. Protection Functions
Input Protection: Overload protection (no short-circuit/ground fault)B& R Industrial Automation
Thermal Protection: Over-temperature monitoring for power componentsB& R Industrial Automation
Voltage Protection: DC bus over/undervoltage monitoringB& R Industrial Automation
Regeneration Protection: Overvoltage protection during energy regenerationB& R Industrial Automation
9. Accessories
9.1 Mandatory
Terminal Block Set: 8BZVP044000.000-1AB& R Industrial Automation
9.2 Optional
Plug-in Modules: EnDat 2.2 (8BAC0120.001-2), HIPERFACE (8BAC0121.000-1), resolver (8BAC0122.000-1), etc.B& R Industrial Automation
Fan Module: 8BXF001.0000-00B& R Industrial Automation
Shield Kits: 8SCS002.0000-00, 8SCS008.0000-00B& R Industrial Automation
Cables: POWERLINK/Ethernet (X20CA0E61.00020–X20CA0E61.00100)B& R Industrial Automation
10. Typical Applications
Multi-axis CNC machine tools and machining centersB& R Industrial Automation
High-power automated assembly and production linesB& R Industrial Automation
Packaging, printing, and textile machinery with regenerative loadsB& R Industrial Automation
Logistics conveying systems with frequent start/stop operationsB& R Industrial Automation
Industrial robots and heavy-duty motion control systemsB& R Industrial Automation
Get a Quote