I. Core Parameters (D633-442B-RO2KO1FONSS2 Official Standard)
1. Basic Specifications
Model: D633-442B-RO2KO1FONSS2 (NG6 Direct Acting Servo Valve)
Flow Specification: 40 L/min @ Δp=35 bar
Pressure Rating:
P/A/B: 350 bar
T/Y: 350 bar (with Y port high-pressure return oil)
Frequency Response: 320–380 Hz (−3dB)
Step Response: ≤6 ms (0→100%)
Leakage: <0.3 L/min (neutral position)
Valve Core Type: Standard zero coverage, linear gain (R)
Neutral Function: O type (fully closed, O)
Sealing Material: NBR (−20 to +80°C)
Weight: Approximately 3.2 kg
Installation Standard: NG6 / ISO 4401-03
2. Electrical Parameters (Suffix Customization)
Power Supply: 24VDC (18–32V), V
Control Signal: ±10V Analog Voltage, K
Feedback: Built-in LVDT valve core position closed-loop, 1
Interface: 6+PE Aviation Plug, 02
Hysteresis: <0.2%
Resolution: <0.1%
Electronic Board: Integrated PWM Drive, Closed-loop Control
3. Model Segmentation Analysis (RO2KO1FONSS2)
R: Standard Valve Core (Zero Coverage)
O2: 6+PE Aviation Plug (O = Circular Connector)
K: ±10V Control Signal
O: O-type Neutral (Fully Closed)
1: Built-in LVDT Position Feedback
F: FKM Fluororubber High Temperature Seal (−20 to +150°C)
O: Standard Gain, No Offset
N: Low Pressure Return Oil (T port ≤ 210 bar)
SS: Standard Valve Body Coating
2: Version Number (Latest Standard Configuration)
4. Panel and Identification
Valve Body: MOOG Label, Model, Serial Number, Pressure Marking
Electrical Connectors: 6+PE Pin Definitions (Power, Command, Feedback)
5. Key Features
Direct Drive without Pilot: Strong anti-pollution, no pilot leakage, high reliability
Linear Force Motor: Bidirectional large thrust, dynamic and pressure independent
LVDT Closed Loop: High precision, high repeat positioning, low hysteresis
High Temperature Seal: FKM Fluororubber, suitable for high-temperature hydraulic oil conditions
Power-off Safety: Spring centering, load stop
II. Typical Application Scenarios
High-speed Precision Press Machines, High-frequency Dynamic Test Bases
High-speed Robot Joints, Flight / Motion Simulator
High-temperature conditions (+120 to +150°C) Hydraulic Systems
High Precision Closed-loop Control of Position / Speed / Pressure
Ordinary Pressure Return Oil (Non-high-pressure accumulator circuit)
Get a Quote