D632-108B
Description
I. Explanation of Model Number
D632: D632 series two-stage nozzle flap proportional valve (high pressure, large flow)
108: Flow code 10 = 38 L/min (Δp = 10 bar); 8 = internal pilot + standard leakage + highly stable / anti-vibration valve core
B: Form A25 installation surface + NBR (nitrile rubber) seal (-20 to +95℃)
Sentence: D632-108B = 38L/min high flow + internal pilot without Y port + A25 large installation surface + NBR standard seal + standard leakage + highly stable anti-vibration + 280bar high pressure proportional valve
II. Core Parameters (Δp = 10 bar)
Rated flow: 38 L/min
Maximum pressure: 280 bar
Hysteresis: ≤ 4% (between 106B and 107B)
Resolution: ≤ 1%
Zero leakage: ≈ 1.8 L/min (70 bar) (same as 101B standard leakage)
Pilot method: internal pilot (without Y port, main oil circuit self-taken)
Sealing / Temperature: NBR (-20 to +95℃)
Coil: 28Ω, ±100mA, 0.14W
Filter: NAS 7 / ISO 4406 15/12
Features: Strong anti-vibration, good zero stability, small long-term drift
III. Positioning of D632-108B (101B/106B/107B/108B comparison) Table
Model Flow Rate Pre-先导 Leakage (70bar) Hysteresis Core Features
101B 38L/min Internal Pre-先导 ≈2.0 L/min ≤5% Basic model, standard leakage
106B 38L/min Internal Pre-先导 ≈0.8 L/min ≤5% Low leakage, energy-saving
107B 38L/min Internal Pre-先导 ≈0.5 L/min ≤3% Ultra-low leakage, high frequency response, top configuration
108B 38L/min Internal Pre-先导 ≈1.8 L/min ≤4% Standard leakage + high stability / anti-vibration
In one sentence: 108B is the "Stable Type" - with the same internal pre-先导 and flow rate as 101B, the leakage is close to that of 101B, but the anti-vibration / zero position stability has been significantly improved, suitable for working conditions with large vibration and high stability requirements.
Four. Application Scenarios (D632-108B)
High flow rate and high pressure + strong vibration environment: Metallurgical rolling mills, vibrating presses with large vibration, heavy construction machinery
Long-term continuous operation, high zero position stability requirements, small drift
No independent pre-先导 source, simplified oil circuit (without Y port)
Oil temperature ≤ 95℃, ordinary mineral hydraulic oil
A25 large installation surface, high flow rate, high pressure (≤ 280 bar) + anti-vibration + high stability
Not pursuing the ultimate low leakage, but reliable, durable, and low maintenance
Get a Quote