D631-730C
Description
I. Model Meaning
D631: 631 Series Two-stage Mechanical Feedback Servo Valve
730: Flow Code → 30 L/min @ 35 bar (Medium and Small Flow, Precise Control Grade)
C: Built-in Pilot Supply Oil, NBR Seal, Standard Zero Position (General Industrial / Precise Closed-loop Preferred)
II. Core Parameters (Δp = 35 bar / Each Side)
Rated Flow: 30 L/min
Maximum Working Pressure: 315 bar
Frequency Response (−3 dB, 90°): ≈ 60–70 Hz (Excellent Dynamic Performance for Medium and Small Flow)
Step Response (100%): ≈ 20–25 ms
Hysteresis: ≤ 0.3%
Resolution: ≤ 0.1%
Zero Position Leakage: ≈ 0.8 L/min (Extremely Low Leakage in Small Flow Valves)
Pilot Supply Oil: Built-in (Draws oil from Port P)
Temperature Range: −20 ℃ ~ +80 ℃ (Oil)
Filter Requirements: NAS 6–7 Grade / ISO 4406 <14/11
III. Comparison of Key Models in the Same Series (Δp = 35 bar) Table
Model Flow Rate L/min Pre-charge Method Zero Leakage L/min Primary Application
D631-730C 30 Internal ≈0.8 Precision closed-loop, low-flow high-pressure, general industrial
D631-404C 15 Internal ≈0.4 Ultra-precision, extremely low leakage, laboratory / test bench
D631-346C 75 Internal ≈1.2 Medium flow, high-pressure industrial standard
D631-335CF 120 External <2.5 Generating EH, large flow, high stability
D631-502F 150 External ≈2.0 Generating EH, extremely large flow, high pressure
IV. Features and Applications Characteristics
✅ Small flow rate (30 L/min) + Built-in pilot, system simplified, cost low
✅ Extremely low zero-point leakage (≈0.8 L/min), energy-saving, low heat generation
✅ High resolution, low hysteresis, preferred for precise position/velocity/pressure closed-loop control
✅ Built-in pilot without external X port, convenient installation and debugging
Typical applications
Industrial automation: Precision presses, injection molding machines, die-casting machines for closed-loop control
Testing equipment: Material testing machines, fatigue test benches, dynamic loading systems
Metallurgy: Roll-down, tension control, precise roll gap adjustment
General high-pressure: Small flow rate, high precision, high stability closed-loop scenarios