F8652E
Description
HIMA F8652E (SIL3 safety CPU, HIQuad H41q/H51q system)
F8652E is a SIL3-level safety CPU module from German HIMA Black Horse. It belongs to the HIQuad H41q/H51q series and is used in safety instrument systems (SIS), responsible for core safety controls such as safety interlocks and emergency shutdown (ESD).
I. Basic Information
Model: F8652E (Part Number: 984865264)
Brand: HIMA (Germany)
Series: HIQuad H41q/H51q (SIS Safety System)
Type: Dual CPU Locked-Step Redundant Safety Controller
Safety Level: IEC 61508 SIL3 (TÜV Certified), ISO 13849 PL e
Installation: 19" Rack, 4SU Width (Thin Type)
Status: In Service, F865x Series Economy CPU
II. Hardware Core Specifications
Processor: 2 × 32-bit RISC, 25MHz, dual CPU lock-step redundancy
Memory (per CPU):
System Flash: 512KB
User Program Flash: 1MB
Data SRAM: 512KB (specific for security logic)
Dimensions: 163mm × 38mm × 58mm (length × width × height)
Weight: Approximately 0.4kg (light and compact)
III. Electrical Parameters
Power Supply: 24VDC (18~30VDC), redundant power input
Power Consumption: Typical 3W, maximum ≤ 5W
Safety Watchdog: 24V output, 500mA, short-circuit protection
IV. Communication Interfaces (Reduced Version)
Serial Port: 2 × RS232/RS485 (optional, supports Modbus RTU)
Ethernet: Single port 10/100Mbps (Modbus TCP/IP, HIMax protocol)
Backplane Bus: Special I/O bus, connects H41q/H51q series I/O modules
Expansion: Can be equipped with F8627X and other communication modules, supports fiber optic / redundant networking
V. Environmental and Reliability
Operating Temperature: -20℃ ~ +60℃ (industrial wide temperature range)
Storage Temperature: -40℃ ~ +85℃
Humidity: 5%~95%, no condensation
Protection Grade: IP20 (dust-proof, used in cabinet)
Redundancy: Dual CPU lock-step operation, automatic fault switching, no single point failure
Maintenance: Supports hot swapping, redundant system can be replaced online without interruption
VI. Core Functions (Position: Economical and Practical Type)
SIL3 Safety Control: Meets IEC 61508 SIL3, suitable for ESD, F&G, safety interlock.
Dual CPU Redundancy: Lock-step operation, real-time comparison, fault-safe shutdown, high reliability.
Medium I/O Capacity: Supports up to 1024 points of I/O, suitable for small and medium-sized SIS projects.
Fast Response: Cycle time 20ms, meets the real-time requirements of conventional safety logic.
Multi-Protocol Communication: Ethernet + Serial Port, supports Modbus TCP/RTU, HIMax, easy to integrate with DCS/PLC.