F8627X (HIMA Enhanced Safety Ethernet Communication Module) Basic Information Model: F8627X Brand: HIMA (Germany's HIMA) Type: H41q/H51q System SIL3 Safety Ethernet Communication Module (Enhanced Version) Safety Level: IEC 61508 SIL3, TÜV Certified Part Number: 984862765 Installation: 19-inch rack, occupying 1 slot (compatible with F8627) Protection Level: IP20 Weight: Approximately 0.5kg

Description

F8627X (HIMA Enhanced Safety Ethernet Communication Module) Basic Information

Model: F8627X

Brand: HIMA (Germany's HIMA)

Type: H41q/H51q System SIL3 Safety Ethernet Communication Module (Enhanced Version)

Safety Level: IEC 61508 SIL3, TÜV Certified

Part Number: 984862765

Installation: 19-inch rack, occupying 1 slot (compatible with F8627)

Protection Level: IP20

Weight: Approximately 0.5kg

Electrical parameters

Power supply: 5VDC (backplane, 2A), 24VDC (system)

Power consumption: Typical 5W, maximum 10W

Insulation withstand voltage: Communication interface to ground 500V AC/1 minute

Built-in protection: Overvoltage, undervoltage, reverse connection, overtemperature, short circuit protection

Hardware performance

Processor: 32-bit secure communication processor, hardware-level fault self-diagnosis

Memory: 4MB Flash (firmware), 8MB SDRAM (data)

Architecture: TMR triple redundancy, dual bus fault tolerance

Diagnostic coverage: ≥99% (link / hardware / protocol fault detection)

Response time: ≤10ms (safe data interaction)

Communication interface

Ethernet: 1×RJ45, 10/100Base-TX (IEEE 802.3)

High-speed serial (HSR): 1×RJ12, redundant module interconnection

Debug port: 1×RS-232 (DB9), local configuration / diagnosis

Protocol support: SafeEthernet, Modbus TCP, OPC DA, OPC A&E, ELOP II

Transmission rate: Ethernet maximum 100Mbps

Environmental parameters

Operating temperature: -20℃ ~ +60℃

Storage temperature: -40℃ ~ +85℃

Relative humidity: 5%~95%, no condensation

Vibration / shock: Compliant with IEC 60068 industrial standards

MTBF: >1,000,000 hours Core function

Multi-protocol Secure Communication: SIL3 SafeEthernet + Open Protocol (Modbus TCP/OPC), multi-purpose in one network

Redundancy and Fault Tolerance: Dual-module / Dual-link redundancy, automatic fault switching, no data loss

Protocol Conversion: Seamless interconnection between HIMA system and DCS/PLC/HMI, supports alarm event upload (OPC A&E)

Real-time Diagnosis: Self-diagnosis of hardware / link / protocol faults, fault reporting does not affect safe operation

Hot Swap: Supports online replacement, automatically synchronizes configuration and status after replacement

Panel Indicators

PWR Green: Power normal, always on

RUN Green: Operation normal, flashing

ALM Red: Hardware / communication fault alarm

ETH Yellow: Ethernet data transmission and reception flashing

HSR Yellow: High-speed serial communication flashing

F8627X vs F8627 (Core Differences)

F8627: Basic version, only supports SafeEthernet, OPC DA; Part Number 984862760

F8627X: Enhanced version, adds Modbus TCP, OPC A&E; Part Number 984862765; Fully compatible with F8627, can be directly replaced

Installation and Maintenance

Insert and lock the slot to ensure reliable connection of the backplane contacts

Connect Ethernet / HSR / Debug interfaces according to specifications, and ground the cabinet reliably

Check the status of indicator lights during daily inspections, regularly tighten terminals and clean dust

Direct replacement of the same model is allowed, no need to reconfigure programs and addresses