F8621A
Description
F8621A (HIMA Secure Communication Coprocessor Module) Basic Information
Model: F8621A (often written as F8621/A)
Brand: HIMA (German HIMA)
Type: H41q/H51q System Safety Communication Coprocessor (to share the communication load of the main CPU)
Safety level: IEC 61508 SIL3, TÜV Certification
Part number: 984862160
Installation: Rack slot type (occupies 1 slot)
Protection level: IP20
Weight: Approximately 0.18kg
Electrical parameters
Power supply: 5VDC (backplane), 24VDC dual power supply
Power consumption: Typical 7W (5V backplane power supply)
Insulation withstand voltage: Input / communication interface to ground 500V AC / 1 minute
Built-in protection: Overvoltage, undervoltage, reverse connection, overtemperature, short circuit protection
Hardware performance
Processor: 400MHz PowerPC (independent communication core)
Memory: 32MB SDRAM, 8MB Flash (firmware / configuration)
Backplane bus: 1Gbit/s fault-tolerant safety bus (dual-port RAM interaction)
Architecture: Coordinated with the main CPU (F8650X/F8652X), TMR triple redundancy
Periodic load: Can offload the communication load of the main CPU up to 70%
Communication interface
Ethernet: 1× RJ45 10/100Base-TX (Modbus TCP, OPC, SNMP, NTP)
Serial port: 2× isolated RS-485 (PROFIBUS DP-V1 master / slave station, up to 126 slave stations per port)
System bus: HIMA dedicated redundant safety backplane bus
Supported protocols: PROFIBUS DP-V0/V1, Modbus RTU master / slave, Modbus TCP, ELOP II/SILworX diagnosis
Environmental parameters
Operating temperature: -20℃ ~ +60℃
Storage temperature: -40℃ ~ +85℃
Relative humidity: 5%~95%, no condensation
Vibration / shock: Compliant with IEC 60068 industrial standard
MTBF: >1,100,000 hours Core function
Communication Offloading: Independently process fieldbus/ethernet data, reducing the load on the main CPU
Redundant Communication: Dual RS-485 + Ethernet multi-link redundancy, automatic failover in case of failure
Real-time Diagnosis: Full self-diagnosis of hardware/links, fault reporting does not affect safety interlock
Hot Swap: Supports online replacement, automatically synchronizes configuration after replacement
Protocol Conversion: Achieve data intercommunication between SIS and DCS/PLC/HMI
Panel Indicator Lights
PWR Green: Power normal, constantly on
RUN Green: Operation normal, flashing
ALM Red: Hardware/communication failure alarm
ETH Yellow: Ethernet data transmission and reception flashing
COM Yellow: RS-485 / backplane bus communication flashing
Installation and Maintenance
The rack slot is pushed in and locked to ensure reliable backplane contacts
Connect power, Ethernet / serial port in accordance with specifications, and the cabinet is reliably grounded
Check the status of indicator lights during daily inspections, regularly tighten terminals, and clean dust
Replace with the same model directly, no need to reconfigure programs and addresses