F3322
Description
I. Basic Information
Model: F3322
Brand: HIMA Black Horse (Germany)
Series: HIMatrix F3 Series
Type: 16-channel SIL3 safety digital output module
Application: ESD, BMS, F&G, SIS safety instrumented system, driving solenoid valves, relays, indicator lights, etc.
Software: SILworX
Safety Level: SIL3 (IEC 61508), TÜV AK6, Cat.4/PL e
Architecture: Single-module safety output, supports TMR system expansion
Status: In production
II. Hardware Parameters
Power Supply: 24VDC, -15% to +20%
Power Consumption: Approximately 12W
Output Channels: 16 digital output channels
Output Types: Selectable from source type / drain type, open collector or push-pull
Output Voltage: 24VDC
Single Channel Current: Maximum 0.5A
Isolation: Channel-to-channel / ground 2kVrms
Operating Temperature: -25℃ to +60℃
Storage Temperature: -40℃ to +85℃
Protection: IP20
Size: 25mm × 203mm × 127mm
Weight: Approximately 0.7kg
Hot Swap: Supported
III. Interfaces and Protection
Output Terminals: 16 DO + common terminal, screw terminals
Status Indicators: LED per channel (operation / fault)
Protection Functions: Short circuit protection per channel, overcurrent protection, overvoltage protection
Communication: Backplane bus (for communication with F3311/F3313/F3318 CPU)
IV. Performance and Safety
Response Time: ≤ 5ms
Self-Diagnosis: Channel-level diagnosis (short circuit, open circuit, overload)
Fault Behavior: Single-channel fault does not affect other channels, system alarms and records
Safety Mechanism: Output circuit redundancy detection, output cut-off to safety state in case of failure
V. User Manual (Operation Points)
Installation and Fixation
Insert the module into the F3 series chassis backplane slot, push in the latch to lock; leave a 20mm heat dissipation gap above and below, away from strong electricity / frequency conversion interference.
Power Connection
Connect to a 24VDC regulated power supply, corresponding positive and negative terminals; reliable grounding of FG protective ground to reduce EMC interference.
Output Connection
16 DO terminals are connected to the field equipment (electromagnetic valve / relay coil positive pole), the common terminal is connected to the negative pole of 24VDC; each channel current ≤ 0.5A, to avoid overload.
Software Configuration (SILworX)
Add F3322 in hardware configuration; define each channel usage (interlock / alarm / drive); configure fault response (hold / safety state); compile and download to CPU.
Daily Maintenance
Regularly check terminal tightening and LED status; faults are located by software diagnosis for channels; support hot swap replacement without shutdown.
Compatibility and Replacement
Can be paired with F3311/F3313/F3318 CPU and F32xx DI module in the same chassis; when replacing, update the configuration without modifying the wiring.