Description
HIMA B4243
B4243 is a high-precision analog signal isolation module from the H41q/H51q series of HIMA (Black Horse) from Germany. It belongs to the SIL3 safety level I/O component and is used for electrical isolation and anti-interference of analog signals in safety instrumented systems (SIS).
Basic Information
Model: B4243
Brand/series: HIMA / H41q, H51q (compatible with HIMax system)
Type: Analog signal isolation module (single channel)
Safety level: SIL3, Cat.4, PL e (TÜV certified, IEC 61508)
Application: Special card for industrial safety system analog signal isolation, resistant to strong interference and high stability
Core parameters
Input signal: 0–10V DC (standard analog voltage)
Output signal: 0–10V DC (linearly corresponding after isolation)
Isolation voltage: 2500V DC (input/output/backplane three isolation)
Channel number: 1 channel (single-channel analog signal isolation)
Accuracy: ±0.1% (full scale, 25℃)
Operating temperature: -20℃ ~ +70℃ (wide temperature industrial grade)
Power consumption: ≤5W (24VDC supply)
Protection level: IP20
Size/weight: Standard HIMA card size, approximately 0.3kg
Key features
Three isolation design: Complete electrical isolation between input, output, and system backplane, blocking ground circulation and noise interference
High-precision linear conversion: Precise analog circuitry, no signal distortion or drift, suitable for high-precision measurement scenarios
Fault safety (Fail-Safe): When the module fails, the output defaults to 0V, complying with the principle of safe system power loss
Wide temperature and strong anti-interference: Stable operation at -20℃ ~ +70℃, resistant to EMI/RFI interference, suitable for harsh environments such as petrochemical and power plants
Hot-swappable support: Online replacement of modules does not affect system operation, reducing maintenance downtime
Typical applications
Petrochemical ESD system: Analog signal isolation (pressure, temperature, level) to prevent interference causing false interlocks
Power plant BMS/FSS system: Analog signal isolation for boilers / steam turbines, ensuring stable control of combustion and furnace safety
Natural gas long-distance pipeline SIS: Pressure / flow analog signal isolation to ensure reliable emergency shutdown logic
Coal chemical / metallurgical high-risk facilities: Anti-interference isolation of key process parameter analog signals to meet SIL3 safety requirements
Model differences (B4243 vs B4235)
B4243: Analog signal isolation (0–10V), 2500V isolation, SIL3, single channel
B4235: Digital signal isolation (5V logic), 1500V isolation, SIL3, multi-channel