PR6424/006-030+CON021
Description
I. Model Interpretation PR6424/006-030
PR6424: Φ16mm eddy current sensor, M18×1.5 thread
006: 6 meters double-layer shielded armored cable
030: Standard calibration version
II. Core Parameters of the Sensor
Probe Diameter: 16mm
Installation Thread: M18×1.5
Cable Length: 6m Armored Shielded
Linear Measurement Range: 0 - 4.0mm
Sensitivity: 4V/mm
Standard Installation Gap: 3.0mm
Working Point Voltage (with CON021): -12V
Frequency Response: 0 - 12kHz
Coil Resistance: 5 - 8Ω
Operating Temperature: -35℃ - +150℃
Protection Level: IP67
Compatible Material: 42CrMo4 Ferromagnetic Alloy Steel
III. Parameters of the CON021 Preamplifier
Power Supply: -24VDC (allowable range: -18 to -30VDC)
Output Range: -4V - -20V
Power Consumption: ≤ 2W
Frequency Response: 0 - 10kHz
Includes Reverse Connection, Short Circuit, Open Circuit Protection
Installation: Panel Installation Inside Control Cabinet
IV. Definition of Wiring Terminal
CON021:
1 Pin: -24V
2 Pin: 0V Ground
3 Pin: Signal Output (connected to TSI Module)
4 Pin: Signal Common Ground
V. Installation and Commissioning Specifications
Align the probe vertically to the axis surface, leaving an initial gap of 3.0mm
Power on to adjust the probe, lock the preamplifier with -12V output for fixation
Insert the LEMO plug of the probe into CON021 and tighten to lock
Single-point grounding of the shielding layer on the cabinet side, with the probe end suspended
Keep the cable away from power lines and frequency converters to avoid electromagnetic interference
VI. Application Scope
Used for steam turbines, compressors, large fans
Monitoring: Axial Vibration, Axial Displacement, Temperature Difference, Eccentricity
Compatible: MMS6000, AMS6500 TSI System

Get a Quote